{"title":"Buck-Boost Transformers","description":"\u003cp\u003eMicron buck-boost transformers, 50 VA to 7.5 kVA, single phase, 600 V class. Group A: 120 x 240 V primary, 16\/32 V secondary. Group B: 240 x 480 V primary, 24\/48 V secondary. Group C: 120 x 240 V primary, 12\/24 V secondary. Size on load amps x secondary volts, then pick the next VA size up. Each part page lists the old Micron J number and the Acme, Square D, Eaton, GE, HPS and Jefferson crosses.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/request-a-quote?part=Micron%20buck-boost%20transformer\"\u003eRequest a quote\u003c\/a\u003e · \u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\"\u003eBook 30 minutes to review the application\u003c\/a\u003e\u003c\/p\u003e","products":[{"product_id":"micron-jh050a1eb1a14-50va-buck-boost-transformer-group-a","title":"JH050A1EB1A14 Micron 50 VA Buck-Boost Transformer, Group A, 120x240V to 16\/32V (replaces J050A1EB1A01)","description":"\u003cstyle\u003e.aci-bb table{width:100%;border-collapse:collapse;margin:1em 0}.aci-bb td{padding:6px 10px;border:1px solid #ddd;color:#1a1a1a !important}.aci-bb th{padding:6px 10px;border:1px solid #ccc;text-align:left;background:#1F3864 !important;color:#ffffff !important}.aci-bb a{color:#1F3864 !important;font-weight:600}.aci-bb .aci-legal{color:#666 !important}.aci-bb a.aci-btn{display:inline-block;background:#1F3864 !important;color:#ffffff !important;padding:12px 22px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 10px 10px 0}.aci-bb a.aci-sec{background:#ffffff !important;color:#1F3864 !important;border:2px solid #1F3864;padding:10px 20px}\u003c\/style\u003e\n\u003cdiv class=\"aci-bb\"\u003e\n\u003cp\u003e\u003cstrong\u003eMicron JH050A1EB1A14 is a 50 VA Group A buck-boost transformer: 120 x 240 V primary, 16\/32 V secondary, single phase, 600 V class.\u003c\/strong\u003e It is the current number for the old Micron J050A1EB1A01. It crosses to Acme T181054 and Square D 50SV46A.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH050A1EB1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH050A1EB1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eJH050A1EB1A14 specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJH050A1EB1A14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces Micron number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ050A1EB1A01 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicron Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuck-boost transformer, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 x 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\/32 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 32 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 A max (VA \/ 32 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 16 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.1 A max (VA \/ 16 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year (Micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: FactoryMation Micron buck-boost Group A listing (current JH number, weight, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eCross reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicron (old)\u003c\/td\u003e\n\u003ctd\u003eJ050A1EB1A01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcme\u003c\/td\u003e\n\u003ctd\u003eT181054\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton Cutler-Hammer\u003c\/td\u003e\n\u003ctd\u003eS10N06A81N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPC\u003c\/td\u003e\n\u003ctd\u003eK1XGF16-0.05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003ctd\u003e9T51B0122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPS (Hammond Power Solutions)\u003c\/td\u003e\n\u003ctd\u003eQC05ESCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJefferson\u003c\/td\u003e\n\u003ctd\u003e416-1200-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003ctd\u003e50SV46A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003cp\u003eIn buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 16 or 32 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y\/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.\u003c\/p\u003e\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat replaces Micron J050A1EB1A01?\u003c\/strong\u003e\u003cbr\u003eJH050A1EB1A14. Same Group A, 120 x 240 V primary, 16\/32 V secondary, 50 VA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Micron part replaces Acme T181054?\u003c\/strong\u003e\u003cbr\u003eJH050A1EB1A14, 50 VA, Group A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much load can a 50 VA buck-boost carry?\u003c\/strong\u003e\u003cbr\u003eAbout 1.5 A with the 32 V connection, or 3.1 A with the 16 V connection. Send the line volts, load volts and load amps and we check it.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/micron-control-transformers-by-kva\"\u003eMicron control transformers by kVA\u003c\/a\u003e · \u003ca href=\"\/collections\/micron\"\u003eMicron\u003c\/a\u003e · \u003ca href=\"\/collections\/buck-boost-transformers\"\u003eBuck-boost transformers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH050A1EB1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH050A1EB1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Micron Industries","offers":[{"title":"Default Title","offer_id":67567214657826,"sku":"JH050A1EB1A14","price":0.0,"currency_code":"USD","in_stock":true}]},{"product_id":"micron-jh002k1eb1a14-2kva-buck-boost-transformer-group-a","title":"JH002K1EB1A14 Micron 2 kVA Buck-Boost Transformer, Group A, 120x240V to 16\/32V (replaces J002K1EB1A02)","description":"\u003cstyle\u003e.aci-bb table{width:100%;border-collapse:collapse;margin:1em 0}.aci-bb td{padding:6px 10px;border:1px solid #ddd;color:#1a1a1a !important}.aci-bb th{padding:6px 10px;border:1px solid #ccc;text-align:left;background:#1F3864 !important;color:#ffffff !important}.aci-bb a{color:#1F3864 !important;font-weight:600}.aci-bb .aci-legal{color:#666 !important}.aci-bb a.aci-btn{display:inline-block;background:#1F3864 !important;color:#ffffff !important;padding:12px 22px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 10px 10px 0}.aci-bb a.aci-sec{background:#ffffff !important;color:#1F3864 !important;border:2px solid #1F3864;padding:10px 20px}\u003c\/style\u003e\n\u003cdiv class=\"aci-bb\"\u003e\n\u003cp\u003e\u003cstrong\u003eMicron JH002K1EB1A14 is a 2 kVA Group A buck-boost transformer: 120 x 240 V primary, 16\/32 V secondary, single phase, 600 V class.\u003c\/strong\u003e It is the current number for the old Micron J002K1EB1A02. It crosses to Acme T113075 and Square D 2S46F.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH002K1EB1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH002K1EB1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eJH002K1EB1A14 specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJH002K1EB1A14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces Micron number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ002K1EB1A02 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicron Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuck-boost transformer, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 x 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\/32 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 32 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.5 A max (VA \/ 32 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 16 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A max (VA \/ 16 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year (Micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: FactoryMation Micron buck-boost Group A listing (current JH number, weight, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eCross reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicron (old)\u003c\/td\u003e\n\u003ctd\u003eJ002K1EB1A02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcme\u003c\/td\u003e\n\u003ctd\u003eT113075\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton Cutler-Hammer\u003c\/td\u003e\n\u003ctd\u003eS10N06P02P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHevi-Duty\u003c\/td\u003e\n\u003ctd\u003eHS20F2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPC\u003c\/td\u003e\n\u003ctd\u003eK1XGF16-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003ctd\u003e9T51B0132\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPS (Hammond Power Solutions)\u003c\/td\u003e\n\u003ctd\u003eQ002ESCF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJefferson\u003c\/td\u003e\n\u003ctd\u003e416-1271-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003ctd\u003e2S46F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003cp\u003eIn buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 16 or 32 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y\/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.\u003c\/p\u003e\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat replaces Micron J002K1EB1A02?\u003c\/strong\u003e\u003cbr\u003eJH002K1EB1A14. Same Group A, 120 x 240 V primary, 16\/32 V secondary, 2 kVA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Micron part replaces Acme T113075?\u003c\/strong\u003e\u003cbr\u003eJH002K1EB1A14, 2 kVA, Group A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much load can a 2 kVA buck-boost carry?\u003c\/strong\u003e\u003cbr\u003eAbout 62.5 A with the 32 V connection, or 125 A with the 16 V connection. Send the line volts, load volts and load amps and we check it.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/micron-control-transformers-by-kva\"\u003eMicron control transformers by kVA\u003c\/a\u003e · \u003ca href=\"\/collections\/micron\"\u003eMicron\u003c\/a\u003e · \u003ca href=\"\/collections\/buck-boost-transformers\"\u003eBuck-boost transformers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH002K1EB1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH002K1EB1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Micron Industries","offers":[{"title":"Default Title","offer_id":67567214985506,"sku":"JH002K1EB1A14","price":0.0,"currency_code":"USD","in_stock":true}]},{"product_id":"micron-jh100a1eb1a14-100va-buck-boost-transformer-group-a","title":"JH100A1EB1A14 Micron 100 VA Buck-Boost Transformer, Group A, 120x240V to 16\/32V (replaces J100A1EB1A01)","description":"\u003cstyle\u003e.aci-bb table{width:100%;border-collapse:collapse;margin:1em 0}.aci-bb td{padding:6px 10px;border:1px solid #ddd;color:#1a1a1a !important}.aci-bb th{padding:6px 10px;border:1px solid #ccc;text-align:left;background:#1F3864 !important;color:#ffffff !important}.aci-bb a{color:#1F3864 !important;font-weight:600}.aci-bb .aci-legal{color:#666 !important}.aci-bb a.aci-btn{display:inline-block;background:#1F3864 !important;color:#ffffff !important;padding:12px 22px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 10px 10px 0}.aci-bb a.aci-sec{background:#ffffff !important;color:#1F3864 !important;border:2px solid #1F3864;padding:10px 20px}\u003c\/style\u003e\n\u003cdiv class=\"aci-bb\"\u003e\n\u003cp\u003e\u003cstrong\u003eMicron JH100A1EB1A14 is a 100 VA Group A buck-boost transformer: 120 x 240 V primary, 16\/32 V secondary, single phase, 600 V class.\u003c\/strong\u003e It is the current number for the old Micron J100A1EB1A01. It crosses to Acme T181055 and Square D 100SV46A.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH100A1EB1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH100A1EB1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eJH100A1EB1A14 specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJH100A1EB1A14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces Micron number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ100A1EB1A01 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicron Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuck-boost transformer, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 x 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\/32 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 32 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.1 A max (VA \/ 32 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 16 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.2 A max (VA \/ 16 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year (Micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: FactoryMation Micron buck-boost Group A listing (current JH number, weight, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eCross reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicron (old)\u003c\/td\u003e\n\u003ctd\u003eJ100A1EB1A01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcme\u003c\/td\u003e\n\u003ctd\u003eT181055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton Cutler-Hammer\u003c\/td\u003e\n\u003ctd\u003eS10N06A82N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPC\u003c\/td\u003e\n\u003ctd\u003eK1XGF16-0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003ctd\u003e9T51B0124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPS (Hammond Power Solutions)\u003c\/td\u003e\n\u003ctd\u003eQC10ESCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJefferson\u003c\/td\u003e\n\u003ctd\u003e416-1201-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003ctd\u003e100SV46A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003cp\u003eIn buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 16 or 32 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y\/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.\u003c\/p\u003e\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat replaces Micron J100A1EB1A01?\u003c\/strong\u003e\u003cbr\u003eJH100A1EB1A14. Same Group A, 120 x 240 V primary, 16\/32 V secondary, 100 VA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Micron part replaces Acme T181055?\u003c\/strong\u003e\u003cbr\u003eJH100A1EB1A14, 100 VA, Group A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much load can a 100 VA buck-boost carry?\u003c\/strong\u003e\u003cbr\u003eAbout 3.1 A with the 32 V connection, or 6.2 A with the 16 V connection. Send the line volts, load volts and load amps and we check it.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/micron-control-transformers-by-kva\"\u003eMicron control transformers by kVA\u003c\/a\u003e · \u003ca href=\"\/collections\/micron\"\u003eMicron\u003c\/a\u003e · \u003ca href=\"\/collections\/buck-boost-transformers\"\u003eBuck-boost transformers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH100A1EB1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH100A1EB1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Micron Industries","offers":[{"title":"Default Title","offer_id":67567215018274,"sku":"JH100A1EB1A14","price":0.0,"currency_code":"USD","in_stock":true}]},{"product_id":"micron-jh250a1kc1a14-250va-buck-boost-transformer-group-b","title":"JH250A1KC1A14 Micron 250 VA Buck-Boost Transformer, Group B, 240x480V to 24\/48V (replaces J250A1KC1A02)","description":"\u003cstyle\u003e.aci-bb table{width:100%;border-collapse:collapse;margin:1em 0}.aci-bb td{padding:6px 10px;border:1px solid #ddd;color:#1a1a1a !important}.aci-bb th{padding:6px 10px;border:1px solid #ccc;text-align:left;background:#1F3864 !important;color:#ffffff !important}.aci-bb a{color:#1F3864 !important;font-weight:600}.aci-bb .aci-legal{color:#666 !important}.aci-bb a.aci-btn{display:inline-block;background:#1F3864 !important;color:#ffffff !important;padding:12px 22px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 10px 10px 0}.aci-bb a.aci-sec{background:#ffffff !important;color:#1F3864 !important;border:2px solid #1F3864;padding:10px 20px}\u003c\/style\u003e\n\u003cdiv class=\"aci-bb\"\u003e\n\u003cp\u003e\u003cstrong\u003eMicron JH250A1KC1A14 is a 250 VA Group B buck-boost transformer: 240 x 480 V primary, 24\/48 V secondary, single phase, 600 V class.\u003c\/strong\u003e It is the current number for the old Micron J250A1KC1A02. It crosses to Acme T181064 and Square D 250SV82B.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH250A1KC1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH250A1KC1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eJH250A1KC1A14 specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJH250A1KC1A14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces Micron number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ250A1KC1A02 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicron Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuck-boost transformer, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 x 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\/48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 48 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.2 A max (VA \/ 48 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 24 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.4 A max (VA \/ 24 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year (Micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: FactoryMation Micron buck-boost Group B listing (current JH number, weight, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eCross reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicron (old)\u003c\/td\u003e\n\u003ctd\u003eJ250A1KC1A02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcme\u003c\/td\u003e\n\u003ctd\u003eT181064\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton Cutler-Hammer\u003c\/td\u003e\n\u003ctd\u003eS20N08P26P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHevi-Duty\u003c\/td\u003e\n\u003ctd\u003eHS22B250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPC\u003c\/td\u003e\n\u003ctd\u003eK2XGF24-0.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003ctd\u003e9T51B0207\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPS (Hammond Power Solutions)\u003c\/td\u003e\n\u003ctd\u003eQC25DTCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJefferson\u003c\/td\u003e\n\u003ctd\u003e416-1421-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003ctd\u003e250SV82B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003cp\u003eIn buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 24 or 48 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y\/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.\u003c\/p\u003e\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat replaces Micron J250A1KC1A02?\u003c\/strong\u003e\u003cbr\u003eJH250A1KC1A14. Same Group B, 240 x 480 V primary, 24\/48 V secondary, 250 VA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Micron part replaces Acme T181064?\u003c\/strong\u003e\u003cbr\u003eJH250A1KC1A14, 250 VA, Group B.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much load can a 250 VA buck-boost carry?\u003c\/strong\u003e\u003cbr\u003eAbout 5.2 A with the 48 V connection, or 10.4 A with the 24 V connection. Send the line volts, load volts and load amps and we check it.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/micron-control-transformers-by-kva\"\u003eMicron control transformers by kVA\u003c\/a\u003e · \u003ca href=\"\/collections\/micron\"\u003eMicron\u003c\/a\u003e · \u003ca href=\"\/collections\/buck-boost-transformers\"\u003eBuck-boost transformers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH250A1KC1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH250A1KC1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Micron Industries","offers":[{"title":"Default Title","offer_id":67567215051042,"sku":"JH250A1KC1A14","price":0.0,"currency_code":"USD","in_stock":true}]},{"product_id":"micron-jh150a1eb1a14-150va-buck-boost-transformer-group-a","title":"JH150A1EB1A14 Micron 150 VA Buck-Boost Transformer, Group A, 120x240V to 16\/32V (replaces J150A1EB1A01)","description":"\u003cstyle\u003e.aci-bb table{width:100%;border-collapse:collapse;margin:1em 0}.aci-bb td{padding:6px 10px;border:1px solid #ddd;color:#1a1a1a !important}.aci-bb th{padding:6px 10px;border:1px solid #ccc;text-align:left;background:#1F3864 !important;color:#ffffff !important}.aci-bb a{color:#1F3864 !important;font-weight:600}.aci-bb .aci-legal{color:#666 !important}.aci-bb a.aci-btn{display:inline-block;background:#1F3864 !important;color:#ffffff !important;padding:12px 22px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 10px 10px 0}.aci-bb a.aci-sec{background:#ffffff !important;color:#1F3864 !important;border:2px solid #1F3864;padding:10px 20px}\u003c\/style\u003e\n\u003cdiv class=\"aci-bb\"\u003e\n\u003cp\u003e\u003cstrong\u003eMicron JH150A1EB1A14 is a 150 VA Group A buck-boost transformer: 120 x 240 V primary, 16\/32 V secondary, single phase, 600 V class.\u003c\/strong\u003e It is the current number for the old Micron J150A1EB1A01. It crosses to Acme T181056 and Square D 150SV46A.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH150A1EB1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH150A1EB1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eJH150A1EB1A14 specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJH150A1EB1A14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces Micron number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ150A1EB1A01 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicron Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuck-boost transformer, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 x 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\/32 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 32 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.6 A max (VA \/ 32 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 16 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.3 A max (VA \/ 16 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year (Micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: FactoryMation Micron buck-boost Group A listing (current JH number, weight, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eCross reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicron (old)\u003c\/td\u003e\n\u003ctd\u003eJ150A1EB1A01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcme\u003c\/td\u003e\n\u003ctd\u003eT181056\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton Cutler-Hammer\u003c\/td\u003e\n\u003ctd\u003eS10N06A83N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHevi-Duty\u003c\/td\u003e\n\u003ctd\u003eHS20B150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPC\u003c\/td\u003e\n\u003ctd\u003eK1XGF16-0.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003ctd\u003e9T51B0125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPS (Hammond Power Solutions)\u003c\/td\u003e\n\u003ctd\u003eQC15ESCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJefferson\u003c\/td\u003e\n\u003ctd\u003e416-1211-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003ctd\u003e150SV46A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003cp\u003eIn buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 16 or 32 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y\/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.\u003c\/p\u003e\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat replaces Micron J150A1EB1A01?\u003c\/strong\u003e\u003cbr\u003eJH150A1EB1A14. Same Group A, 120 x 240 V primary, 16\/32 V secondary, 150 VA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Micron part replaces Acme T181056?\u003c\/strong\u003e\u003cbr\u003eJH150A1EB1A14, 150 VA, Group A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much load can a 150 VA buck-boost carry?\u003c\/strong\u003e\u003cbr\u003eAbout 4.6 A with the 32 V connection, or 9.3 A with the 16 V connection. Send the line volts, load volts and load amps and we check it.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/micron-control-transformers-by-kva\"\u003eMicron control transformers by kVA\u003c\/a\u003e · \u003ca href=\"\/collections\/micron\"\u003eMicron\u003c\/a\u003e · \u003ca href=\"\/collections\/buck-boost-transformers\"\u003eBuck-boost transformers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH150A1EB1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH150A1EB1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Micron Industries","offers":[{"title":"Default Title","offer_id":67567215083810,"sku":"JH150A1EB1A14","price":0.0,"currency_code":"USD","in_stock":true}]},{"product_id":"micron-jh003k1eb1a15-3kva-buck-boost-transformer-group-a","title":"JH003K1EB1A15 Micron 3 kVA Buck-Boost Transformer, Group A, 120x240V to 16\/32V (replaces J003K1EB1A03)","description":"\u003cstyle\u003e.aci-bb table{width:100%;border-collapse:collapse;margin:1em 0}.aci-bb td{padding:6px 10px;border:1px solid #ddd;color:#1a1a1a !important}.aci-bb th{padding:6px 10px;border:1px solid #ccc;text-align:left;background:#1F3864 !important;color:#ffffff !important}.aci-bb a{color:#1F3864 !important;font-weight:600}.aci-bb .aci-legal{color:#666 !important}.aci-bb a.aci-btn{display:inline-block;background:#1F3864 !important;color:#ffffff !important;padding:12px 22px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 10px 10px 0}.aci-bb a.aci-sec{background:#ffffff !important;color:#1F3864 !important;border:2px solid #1F3864;padding:10px 20px}\u003c\/style\u003e\n\u003cdiv class=\"aci-bb\"\u003e\n\u003cp\u003e\u003cstrong\u003eMicron JH003K1EB1A15 is a 3 kVA Group A buck-boost transformer: 120 x 240 V primary, 16\/32 V secondary, single phase, 600 V class.\u003c\/strong\u003e It is the current number for the old Micron J003K1EB1A03. It crosses to Acme T113076 and Square D 3S46F.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH003K1EB1A15\" class=\"aci-btn\"\u003eRequest a Quote for JH003K1EB1A15\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eJH003K1EB1A15 specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJH003K1EB1A15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces Micron number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ003K1EB1A03 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicron Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuck-boost transformer, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 x 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\/32 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 32 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93.7 A max (VA \/ 32 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 16 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187.5 A max (VA \/ 16 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year (Micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: FactoryMation Micron buck-boost Group A listing (current JH number, weight, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eCross reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicron (old)\u003c\/td\u003e\n\u003ctd\u003eJ003K1EB1A03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcme\u003c\/td\u003e\n\u003ctd\u003eT113076\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton Cutler-Hammer\u003c\/td\u003e\n\u003ctd\u003eS10N06A03N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHevi-Duty\u003c\/td\u003e\n\u003ctd\u003eHS20F3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPC\u003c\/td\u003e\n\u003ctd\u003eK1XGF16-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003ctd\u003e9T51B0133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPS (Hammond Power Solutions)\u003c\/td\u003e\n\u003ctd\u003eQ003ESCF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJefferson\u003c\/td\u003e\n\u003ctd\u003e416-1281-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003ctd\u003e3S46F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003cp\u003eIn buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 16 or 32 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y\/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.\u003c\/p\u003e\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat replaces Micron J003K1EB1A03?\u003c\/strong\u003e\u003cbr\u003eJH003K1EB1A15. Same Group A, 120 x 240 V primary, 16\/32 V secondary, 3 kVA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Micron part replaces Acme T113076?\u003c\/strong\u003e\u003cbr\u003eJH003K1EB1A15, 3 kVA, Group A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much load can a 3 kVA buck-boost carry?\u003c\/strong\u003e\u003cbr\u003eAbout 93.7 A with the 32 V connection, or 187.5 A with the 16 V connection. Send the line volts, load volts and load amps and we check it.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/micron-control-transformers-by-kva\"\u003eMicron control transformers by kVA\u003c\/a\u003e · \u003ca href=\"\/collections\/micron\"\u003eMicron\u003c\/a\u003e · \u003ca href=\"\/collections\/buck-boost-transformers\"\u003eBuck-boost transformers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH003K1EB1A15\" class=\"aci-btn\"\u003eRequest a Quote for JH003K1EB1A15\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Micron Industries","offers":[{"title":"Default Title","offer_id":67567215116578,"sku":"JH003K1EB1A15","price":0.0,"currency_code":"USD","in_stock":true}]},{"product_id":"micron-jh500a1kc1a14-500va-buck-boost-transformer-group-b","title":"JH500A1KC1A14 Micron 500 VA Buck-Boost Transformer, Group B, 240x480V to 24\/48V (replaces J500A1KC1A02)","description":"\u003cstyle\u003e.aci-bb table{width:100%;border-collapse:collapse;margin:1em 0}.aci-bb td{padding:6px 10px;border:1px solid #ddd;color:#1a1a1a !important}.aci-bb th{padding:6px 10px;border:1px solid #ccc;text-align:left;background:#1F3864 !important;color:#ffffff !important}.aci-bb a{color:#1F3864 !important;font-weight:600}.aci-bb .aci-legal{color:#666 !important}.aci-bb a.aci-btn{display:inline-block;background:#1F3864 !important;color:#ffffff !important;padding:12px 22px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 10px 10px 0}.aci-bb a.aci-sec{background:#ffffff !important;color:#1F3864 !important;border:2px solid #1F3864;padding:10px 20px}\u003c\/style\u003e\n\u003cdiv class=\"aci-bb\"\u003e\n\u003cp\u003e\u003cstrong\u003eMicron JH500A1KC1A14 is a 500 VA Group B buck-boost transformer: 240 x 480 V primary, 24\/48 V secondary, single phase, 600 V class.\u003c\/strong\u003e It is the current number for the old Micron J500A1KC1A02. It crosses to Acme T181065 and Square D 500SV82B.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH500A1KC1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH500A1KC1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eJH500A1KC1A14 specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJH500A1KC1A14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces Micron number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ500A1KC1A02 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicron Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuck-boost transformer, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 x 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\/48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 48 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.4 A max (VA \/ 48 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 24 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.8 A max (VA \/ 24 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year (Micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: FactoryMation Micron buck-boost Group B listing (current JH number, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eCross reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicron (old)\u003c\/td\u003e\n\u003ctd\u003eJ500A1KC1A02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcme\u003c\/td\u003e\n\u003ctd\u003eT181065\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton Cutler-Hammer\u003c\/td\u003e\n\u003ctd\u003eS20N08P51P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHevi-Duty\u003c\/td\u003e\n\u003ctd\u003eHS22F500B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPC\u003c\/td\u003e\n\u003ctd\u003eK2XGF24-0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003ctd\u003e9T51B0208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPS (Hammond Power Solutions)\u003c\/td\u003e\n\u003ctd\u003eQC50DTCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJefferson\u003c\/td\u003e\n\u003ctd\u003e416-1431-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003ctd\u003e500SV82B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003cp\u003eIn buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 24 or 48 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y\/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.\u003c\/p\u003e\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat replaces Micron J500A1KC1A02?\u003c\/strong\u003e\u003cbr\u003eJH500A1KC1A14. Same Group B, 240 x 480 V primary, 24\/48 V secondary, 500 VA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Micron part replaces Acme T181065?\u003c\/strong\u003e\u003cbr\u003eJH500A1KC1A14, 500 VA, Group B.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much load can a 500 VA buck-boost carry?\u003c\/strong\u003e\u003cbr\u003eAbout 10.4 A with the 48 V connection, or 20.8 A with the 24 V connection. Send the line volts, load volts and load amps and we check it.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/micron-control-transformers-by-kva\"\u003eMicron control transformers by kVA\u003c\/a\u003e · \u003ca href=\"\/collections\/micron\"\u003eMicron\u003c\/a\u003e · \u003ca href=\"\/collections\/buck-boost-transformers\"\u003eBuck-boost transformers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH500A1KC1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH500A1KC1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Micron Industries","offers":[{"title":"Default Title","offer_id":67567215182114,"sku":"JH500A1KC1A14","price":0.0,"currency_code":"USD","in_stock":true}]},{"product_id":"micron-jh250a1eb1a14-250va-buck-boost-transformer-group-a","title":"JH250A1EB1A14 Micron 250 VA Buck-Boost Transformer, Group A, 120x240V to 16\/32V (replaces J250A1EB1A02)","description":"\u003cstyle\u003e.aci-bb table{width:100%;border-collapse:collapse;margin:1em 0}.aci-bb td{padding:6px 10px;border:1px solid #ddd;color:#1a1a1a !important}.aci-bb th{padding:6px 10px;border:1px solid #ccc;text-align:left;background:#1F3864 !important;color:#ffffff !important}.aci-bb a{color:#1F3864 !important;font-weight:600}.aci-bb .aci-legal{color:#666 !important}.aci-bb a.aci-btn{display:inline-block;background:#1F3864 !important;color:#ffffff !important;padding:12px 22px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 10px 10px 0}.aci-bb a.aci-sec{background:#ffffff !important;color:#1F3864 !important;border:2px solid #1F3864;padding:10px 20px}\u003c\/style\u003e\n\u003cdiv class=\"aci-bb\"\u003e\n\u003cp\u003e\u003cstrong\u003eMicron JH250A1EB1A14 is a 250 VA Group A buck-boost transformer: 120 x 240 V primary, 16\/32 V secondary, single phase, 600 V class.\u003c\/strong\u003e It is the current number for the old Micron J250A1EB1A02. It crosses to Acme T181057 and Square D 250SV46B.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH250A1EB1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH250A1EB1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eJH250A1EB1A14 specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJH250A1EB1A14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces Micron number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ250A1EB1A02 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicron Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuck-boost transformer, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 x 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\/32 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 32 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.8 A max (VA \/ 32 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 16 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.6 A max (VA \/ 16 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year (Micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: FactoryMation Micron buck-boost Group A listing (current JH number, weight, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eCross reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicron (old)\u003c\/td\u003e\n\u003ctd\u003eJ250A1EB1A02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcme\u003c\/td\u003e\n\u003ctd\u003eT181057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton Cutler-Hammer\u003c\/td\u003e\n\u003ctd\u003eS10N06P26P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHevi-Duty\u003c\/td\u003e\n\u003ctd\u003eHS20B250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPC\u003c\/td\u003e\n\u003ctd\u003eK1XGF16-0.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003ctd\u003e9T51B0127\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPS (Hammond Power Solutions)\u003c\/td\u003e\n\u003ctd\u003eQC25ESCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJefferson\u003c\/td\u003e\n\u003ctd\u003e416-1221-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003ctd\u003e250SV46B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003cp\u003eIn buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 16 or 32 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y\/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.\u003c\/p\u003e\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat replaces Micron J250A1EB1A02?\u003c\/strong\u003e\u003cbr\u003eJH250A1EB1A14. Same Group A, 120 x 240 V primary, 16\/32 V secondary, 250 VA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Micron part replaces Acme T181057?\u003c\/strong\u003e\u003cbr\u003eJH250A1EB1A14, 250 VA, Group A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much load can a 250 VA buck-boost carry?\u003c\/strong\u003e\u003cbr\u003eAbout 7.8 A with the 32 V connection, or 15.6 A with the 16 V connection. Send the line volts, load volts and load amps and we check it.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/micron-control-transformers-by-kva\"\u003eMicron control transformers by kVA\u003c\/a\u003e · \u003ca href=\"\/collections\/micron\"\u003eMicron\u003c\/a\u003e · \u003ca href=\"\/collections\/buck-boost-transformers\"\u003eBuck-boost transformers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH250A1EB1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH250A1EB1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Micron Industries","offers":[{"title":"Default Title","offer_id":67567216099618,"sku":"JH250A1EB1A14","price":0.0,"currency_code":"USD","in_stock":true}]},{"product_id":"micron-jh005k1eb1a15-5kva-buck-boost-transformer-group-a","title":"JH005K1EB1A15 Micron 5 kVA Buck-Boost Transformer, Group A, 120x240V to 16\/32V (replaces J005K1EB1A03)","description":"\u003cstyle\u003e.aci-bb table{width:100%;border-collapse:collapse;margin:1em 0}.aci-bb td{padding:6px 10px;border:1px solid #ddd;color:#1a1a1a !important}.aci-bb th{padding:6px 10px;border:1px solid #ccc;text-align:left;background:#1F3864 !important;color:#ffffff !important}.aci-bb a{color:#1F3864 !important;font-weight:600}.aci-bb .aci-legal{color:#666 !important}.aci-bb a.aci-btn{display:inline-block;background:#1F3864 !important;color:#ffffff !important;padding:12px 22px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 10px 10px 0}.aci-bb a.aci-sec{background:#ffffff !important;color:#1F3864 !important;border:2px solid #1F3864;padding:10px 20px}\u003c\/style\u003e\n\u003cdiv class=\"aci-bb\"\u003e\n\u003cp\u003e\u003cstrong\u003eMicron JH005K1EB1A15 is a 5 kVA Group A buck-boost transformer: 120 x 240 V primary, 16\/32 V secondary, single phase, 600 V class.\u003c\/strong\u003e It is the current number for the old Micron J005K1EB1A03. It crosses to Acme T113077.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH005K1EB1A15\" class=\"aci-btn\"\u003eRequest a Quote for JH005K1EB1A15\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eJH005K1EB1A15 specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJH005K1EB1A15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces Micron number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ005K1EB1A03 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicron Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuck-boost transformer, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 x 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\/32 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 32 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e156.2 A max (VA \/ 32 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 16 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e312.5 A max (VA \/ 16 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year (Micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: FactoryMation Micron buck-boost Group A listing (current JH number, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eCross reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicron (old)\u003c\/td\u003e\n\u003ctd\u003eJ005K1EB1A03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcme\u003c\/td\u003e\n\u003ctd\u003eT113077\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton Cutler-Hammer\u003c\/td\u003e\n\u003ctd\u003eS10N06A05N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHevi-Duty\u003c\/td\u003e\n\u003ctd\u003eHS20F5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPC\u003c\/td\u003e\n\u003ctd\u003eK1XLF16-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003ctd\u003e9T21B1040G02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPS (Hammond Power Solutions)\u003c\/td\u003e\n\u003ctd\u003eQ005ESCF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJefferson\u003c\/td\u003e\n\u003ctd\u003e416-1291-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003cp\u003eIn buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 16 or 32 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y\/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.\u003c\/p\u003e\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat replaces Micron J005K1EB1A03?\u003c\/strong\u003e\u003cbr\u003eJH005K1EB1A15. Same Group A, 120 x 240 V primary, 16\/32 V secondary, 5 kVA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Micron part replaces Acme T113077?\u003c\/strong\u003e\u003cbr\u003eJH005K1EB1A15, 5 kVA, Group A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much load can a 5 kVA buck-boost carry?\u003c\/strong\u003e\u003cbr\u003eAbout 156.2 A with the 32 V connection, or 312.5 A with the 16 V connection. Send the line volts, load volts and load amps and we check it.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/micron-control-transformers-by-kva\"\u003eMicron control transformers by kVA\u003c\/a\u003e · \u003ca href=\"\/collections\/micron\"\u003eMicron\u003c\/a\u003e · \u003ca href=\"\/collections\/buck-boost-transformers\"\u003eBuck-boost transformers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH005K1EB1A15\" class=\"aci-btn\"\u003eRequest a Quote for JH005K1EB1A15\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Micron Industries","offers":[{"title":"Default Title","offer_id":67567216132386,"sku":"JH005K1EB1A15","price":0.0,"currency_code":"USD","in_stock":true}]},{"product_id":"micron-jh750a1kc1a15-750va-buck-boost-transformer-group-b","title":"JH750A1KC1A15 Micron 750 VA Buck-Boost Transformer, Group B, 240x480V to 24\/48V (replaces J750A1KC1A02)","description":"\u003cstyle\u003e.aci-bb table{width:100%;border-collapse:collapse;margin:1em 0}.aci-bb td{padding:6px 10px;border:1px solid #ddd;color:#1a1a1a !important}.aci-bb th{padding:6px 10px;border:1px solid #ccc;text-align:left;background:#1F3864 !important;color:#ffffff !important}.aci-bb a{color:#1F3864 !important;font-weight:600}.aci-bb .aci-legal{color:#666 !important}.aci-bb a.aci-btn{display:inline-block;background:#1F3864 !important;color:#ffffff !important;padding:12px 22px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 10px 10px 0}.aci-bb a.aci-sec{background:#ffffff !important;color:#1F3864 !important;border:2px solid #1F3864;padding:10px 20px}\u003c\/style\u003e\n\u003cdiv class=\"aci-bb\"\u003e\n\u003cp\u003e\u003cstrong\u003eMicron JH750A1KC1A15 is a 750 VA Group B buck-boost transformer: 240 x 480 V primary, 24\/48 V secondary, single phase, 600 V class.\u003c\/strong\u003e It is the current number for the old Micron J750A1KC1A02. It crosses to Acme T181066 and Square D 750SV82F.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH750A1KC1A15\" class=\"aci-btn\"\u003eRequest a Quote for JH750A1KC1A15\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eJH750A1KC1A15 specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJH750A1KC1A15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces Micron number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ750A1KC1A02 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicron Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuck-boost transformer, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 x 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\/48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 48 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.6 A max (VA \/ 48 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 24 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.2 A max (VA \/ 24 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year (Micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: FactoryMation Micron buck-boost Group B listing (current JH number, weight, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eCross reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicron (old)\u003c\/td\u003e\n\u003ctd\u003eJ750A1KC1A02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcme\u003c\/td\u003e\n\u003ctd\u003eT181066\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton Cutler-Hammer\u003c\/td\u003e\n\u003ctd\u003eS20N08P76P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHevi-Duty\u003c\/td\u003e\n\u003ctd\u003eHS22F750B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPC\u003c\/td\u003e\n\u003ctd\u003eK2XGF24-0.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003ctd\u003e9T51B0209\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPS (Hammond Power Solutions)\u003c\/td\u003e\n\u003ctd\u003eQC75DTCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJefferson\u003c\/td\u003e\n\u003ctd\u003e416-1441-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003ctd\u003e750SV82F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003cp\u003eIn buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 24 or 48 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y\/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.\u003c\/p\u003e\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat replaces Micron J750A1KC1A02?\u003c\/strong\u003e\u003cbr\u003eJH750A1KC1A15. Same Group B, 240 x 480 V primary, 24\/48 V secondary, 750 VA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Micron part replaces Acme T181066?\u003c\/strong\u003e\u003cbr\u003eJH750A1KC1A15, 750 VA, Group B.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much load can a 750 VA buck-boost carry?\u003c\/strong\u003e\u003cbr\u003eAbout 15.6 A with the 48 V connection, or 31.2 A with the 24 V connection. Send the line volts, load volts and load amps and we check it.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/micron-control-transformers-by-kva\"\u003eMicron control transformers by kVA\u003c\/a\u003e · \u003ca href=\"\/collections\/micron\"\u003eMicron\u003c\/a\u003e · \u003ca href=\"\/collections\/buck-boost-transformers\"\u003eBuck-boost transformers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH750A1KC1A15\" class=\"aci-btn\"\u003eRequest a Quote for JH750A1KC1A15\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Micron Industries","offers":[{"title":"Default Title","offer_id":67567216230690,"sku":"JH750A1KC1A15","price":0.0,"currency_code":"USD","in_stock":true}]},{"product_id":"micron-jh500a1eb1a14-500va-buck-boost-transformer-group-a","title":"JH500A1EB1A14 Micron 500 VA Buck-Boost Transformer, Group A, 120x240V to 16\/32V (replaces J500A1EB1A02)","description":"\u003cstyle\u003e.aci-bb table{width:100%;border-collapse:collapse;margin:1em 0}.aci-bb td{padding:6px 10px;border:1px solid #ddd;color:#1a1a1a !important}.aci-bb th{padding:6px 10px;border:1px solid #ccc;text-align:left;background:#1F3864 !important;color:#ffffff !important}.aci-bb a{color:#1F3864 !important;font-weight:600}.aci-bb .aci-legal{color:#666 !important}.aci-bb a.aci-btn{display:inline-block;background:#1F3864 !important;color:#ffffff !important;padding:12px 22px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 10px 10px 0}.aci-bb a.aci-sec{background:#ffffff !important;color:#1F3864 !important;border:2px solid #1F3864;padding:10px 20px}\u003c\/style\u003e\n\u003cdiv class=\"aci-bb\"\u003e\n\u003cp\u003e\u003cstrong\u003eMicron JH500A1EB1A14 is a 500 VA Group A buck-boost transformer: 120 x 240 V primary, 16\/32 V secondary, single phase, 600 V class.\u003c\/strong\u003e It is the current number for the old Micron J500A1EB1A02. It crosses to Acme T181058 and Square D 500SV46B.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH500A1EB1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH500A1EB1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eJH500A1EB1A14 specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJH500A1EB1A14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces Micron number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ500A1EB1A02 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicron Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuck-boost transformer, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 x 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\/32 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 32 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.6 A max (VA \/ 32 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 16 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.2 A max (VA \/ 16 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year (Micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: FactoryMation Micron buck-boost Group A listing (current JH number, weight, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eCross reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicron (old)\u003c\/td\u003e\n\u003ctd\u003eJ500A1EB1A02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcme\u003c\/td\u003e\n\u003ctd\u003eT181058\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton Cutler-Hammer\u003c\/td\u003e\n\u003ctd\u003eS10N06P51P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHevi-Duty\u003c\/td\u003e\n\u003ctd\u003eHS20F500B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPC\u003c\/td\u003e\n\u003ctd\u003eK1XGF16-0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003ctd\u003e9T51B0128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPS (Hammond Power Solutions)\u003c\/td\u003e\n\u003ctd\u003eQC50ESCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJefferson\u003c\/td\u003e\n\u003ctd\u003e416-1231-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003ctd\u003e500SV46B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003cp\u003eIn buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 16 or 32 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y\/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.\u003c\/p\u003e\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat replaces Micron J500A1EB1A02?\u003c\/strong\u003e\u003cbr\u003eJH500A1EB1A14. Same Group A, 120 x 240 V primary, 16\/32 V secondary, 500 VA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Micron part replaces Acme T181058?\u003c\/strong\u003e\u003cbr\u003eJH500A1EB1A14, 500 VA, Group A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much load can a 500 VA buck-boost carry?\u003c\/strong\u003e\u003cbr\u003eAbout 15.6 A with the 32 V connection, or 31.2 A with the 16 V connection. Send the line volts, load volts and load amps and we check it.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/micron-control-transformers-by-kva\"\u003eMicron control transformers by kVA\u003c\/a\u003e · \u003ca href=\"\/collections\/micron\"\u003eMicron\u003c\/a\u003e · \u003ca href=\"\/collections\/buck-boost-transformers\"\u003eBuck-boost transformers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH500A1EB1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH500A1EB1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Micron Industries","offers":[{"title":"Default Title","offer_id":67567216296226,"sku":"JH500A1EB1A14","price":0.0,"currency_code":"USD","in_stock":true}]},{"product_id":"micron-jh050a1kc1a14-50va-buck-boost-transformer-group-b","title":"JH050A1KC1A14 Micron 50 VA Buck-Boost Transformer, Group B, 240x480V to 24\/48V (replaces J050A1KC1A01)","description":"\u003cstyle\u003e.aci-bb table{width:100%;border-collapse:collapse;margin:1em 0}.aci-bb td{padding:6px 10px;border:1px solid #ddd;color:#1a1a1a !important}.aci-bb th{padding:6px 10px;border:1px solid #ccc;text-align:left;background:#1F3864 !important;color:#ffffff !important}.aci-bb a{color:#1F3864 !important;font-weight:600}.aci-bb .aci-legal{color:#666 !important}.aci-bb a.aci-btn{display:inline-block;background:#1F3864 !important;color:#ffffff !important;padding:12px 22px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 10px 10px 0}.aci-bb a.aci-sec{background:#ffffff !important;color:#1F3864 !important;border:2px solid #1F3864;padding:10px 20px}\u003c\/style\u003e\n\u003cdiv class=\"aci-bb\"\u003e\n\u003cp\u003e\u003cstrong\u003eMicron JH050A1KC1A14 is a 50 VA Group B buck-boost transformer: 240 x 480 V primary, 24\/48 V secondary, single phase, 600 V class.\u003c\/strong\u003e It is the current number for the old Micron J050A1KC1A01. It crosses to Acme T181061 and Square D 50SV82A.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH050A1KC1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH050A1KC1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eJH050A1KC1A14 specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJH050A1KC1A14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces Micron number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ050A1KC1A01 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicron Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuck-boost transformer, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 x 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\/48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 48 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 A max (VA \/ 48 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 24 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A max (VA \/ 24 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year (Micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: FactoryMation Micron buck-boost Group B listing (current JH number, weight, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eCross reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicron (old)\u003c\/td\u003e\n\u003ctd\u003eJ050A1KC1A01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcme\u003c\/td\u003e\n\u003ctd\u003eT181061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton Cutler-Hammer\u003c\/td\u003e\n\u003ctd\u003eS20N08A81N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPC\u003c\/td\u003e\n\u003ctd\u003eK2XGF24-0.05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003ctd\u003e9T51B0202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPS (Hammond Power Solutions)\u003c\/td\u003e\n\u003ctd\u003eQC05DTCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJefferson\u003c\/td\u003e\n\u003ctd\u003e416-1400-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003ctd\u003e50SV82A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003cp\u003eIn buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 24 or 48 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y\/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.\u003c\/p\u003e\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat replaces Micron J050A1KC1A01?\u003c\/strong\u003e\u003cbr\u003eJH050A1KC1A14. Same Group B, 240 x 480 V primary, 24\/48 V secondary, 50 VA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Micron part replaces Acme T181061?\u003c\/strong\u003e\u003cbr\u003eJH050A1KC1A14, 50 VA, Group B.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much load can a 50 VA buck-boost carry?\u003c\/strong\u003e\u003cbr\u003eAbout 1 A with the 48 V connection, or 2 A with the 24 V connection. Send the line volts, load volts and load amps and we check it.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/micron-control-transformers-by-kva\"\u003eMicron control transformers by kVA\u003c\/a\u003e · \u003ca href=\"\/collections\/micron\"\u003eMicron\u003c\/a\u003e · \u003ca href=\"\/collections\/buck-boost-transformers\"\u003eBuck-boost transformers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH050A1KC1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH050A1KC1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Micron Industries","offers":[{"title":"Default Title","offer_id":67567216328994,"sku":"JH050A1KC1A14","price":0.0,"currency_code":"USD","in_stock":true}]},{"product_id":"micron-jh001k1kc1a15-1kva-buck-boost-transformer-group-b","title":"JH001K1KC1A15 Micron 1 kVA Buck-Boost Transformer, Group B, 240x480V to 24\/48V (replaces J001K1KC1A02)","description":"\u003cstyle\u003e.aci-bb table{width:100%;border-collapse:collapse;margin:1em 0}.aci-bb td{padding:6px 10px;border:1px solid #ddd;color:#1a1a1a !important}.aci-bb th{padding:6px 10px;border:1px solid #ccc;text-align:left;background:#1F3864 !important;color:#ffffff !important}.aci-bb a{color:#1F3864 !important;font-weight:600}.aci-bb .aci-legal{color:#666 !important}.aci-bb a.aci-btn{display:inline-block;background:#1F3864 !important;color:#ffffff !important;padding:12px 22px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 10px 10px 0}.aci-bb a.aci-sec{background:#ffffff !important;color:#1F3864 !important;border:2px solid #1F3864;padding:10px 20px}\u003c\/style\u003e\n\u003cdiv class=\"aci-bb\"\u003e\n\u003cp\u003e\u003cstrong\u003eMicron JH001K1KC1A15 is a 1 kVA Group B buck-boost transformer: 240 x 480 V primary, 24\/48 V secondary, single phase, 600 V class.\u003c\/strong\u003e It is the current number for the old Micron J001K1KC1A02. It crosses to Acme T137920 and Square D 1S82F.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH001K1KC1A15\" class=\"aci-btn\"\u003eRequest a Quote for JH001K1KC1A15\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eJH001K1KC1A15 specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJH001K1KC1A15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces Micron number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ001K1KC1A02 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicron Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuck-boost transformer, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 x 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\/48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 48 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.8 A max (VA \/ 48 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 24 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41.6 A max (VA \/ 24 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year (Micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: FactoryMation Micron buck-boost Group B listing (current JH number, weight, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eCross reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicron (old)\u003c\/td\u003e\n\u003ctd\u003eJ001K1KC1A02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcme\u003c\/td\u003e\n\u003ctd\u003eT137920\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton Cutler-Hammer\u003c\/td\u003e\n\u003ctd\u003eS20N08P01P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHevi-Duty\u003c\/td\u003e\n\u003ctd\u003eHS22F1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPC\u003c\/td\u003e\n\u003ctd\u003eK2XGF24-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003ctd\u003e9T51B0210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPS (Hammond Power Solutions)\u003c\/td\u003e\n\u003ctd\u003eQ1C0DTCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJefferson\u003c\/td\u003e\n\u003ctd\u003e416-1451-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003ctd\u003e1S82F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003cp\u003eIn buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 24 or 48 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y\/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.\u003c\/p\u003e\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat replaces Micron J001K1KC1A02?\u003c\/strong\u003e\u003cbr\u003eJH001K1KC1A15. Same Group B, 240 x 480 V primary, 24\/48 V secondary, 1 kVA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Micron part replaces Acme T137920?\u003c\/strong\u003e\u003cbr\u003eJH001K1KC1A15, 1 kVA, Group B.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much load can a 1 kVA buck-boost carry?\u003c\/strong\u003e\u003cbr\u003eAbout 20.8 A with the 48 V connection, or 41.6 A with the 24 V connection. Send the line volts, load volts and load amps and we check it.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/micron-control-transformers-by-kva\"\u003eMicron control transformers by kVA\u003c\/a\u003e · \u003ca href=\"\/collections\/micron\"\u003eMicron\u003c\/a\u003e · \u003ca href=\"\/collections\/buck-boost-transformers\"\u003eBuck-boost transformers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH001K1KC1A15\" class=\"aci-btn\"\u003eRequest a Quote for JH001K1KC1A15\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Micron Industries","offers":[{"title":"Default Title","offer_id":67567216361762,"sku":"JH001K1KC1A15","price":0.0,"currency_code":"USD","in_stock":true}]},{"product_id":"micron-jh750a1eb1a15-750va-buck-boost-transformer-group-a","title":"JH750A1EB1A15 Micron 750 VA Buck-Boost Transformer, Group A, 120x240V to 16\/32V (replaces J750A1EB1A02)","description":"\u003cstyle\u003e.aci-bb table{width:100%;border-collapse:collapse;margin:1em 0}.aci-bb td{padding:6px 10px;border:1px solid #ddd;color:#1a1a1a !important}.aci-bb th{padding:6px 10px;border:1px solid #ccc;text-align:left;background:#1F3864 !important;color:#ffffff !important}.aci-bb a{color:#1F3864 !important;font-weight:600}.aci-bb .aci-legal{color:#666 !important}.aci-bb a.aci-btn{display:inline-block;background:#1F3864 !important;color:#ffffff !important;padding:12px 22px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 10px 10px 0}.aci-bb a.aci-sec{background:#ffffff !important;color:#1F3864 !important;border:2px solid #1F3864;padding:10px 20px}\u003c\/style\u003e\n\u003cdiv class=\"aci-bb\"\u003e\n\u003cp\u003e\u003cstrong\u003eMicron JH750A1EB1A15 is a 750 VA Group A buck-boost transformer: 120 x 240 V primary, 16\/32 V secondary, single phase, 600 V class.\u003c\/strong\u003e It is the current number for the old Micron J750A1EB1A02. It crosses to Acme T181059 and Square D 750SV46F.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH750A1EB1A15\" class=\"aci-btn\"\u003eRequest a Quote for JH750A1EB1A15\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eJH750A1EB1A15 specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJH750A1EB1A15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces Micron number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ750A1EB1A02 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicron Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuck-boost transformer, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 x 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\/32 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 32 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23.4 A max (VA \/ 32 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 16 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e46.8 A max (VA \/ 16 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year (Micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: FactoryMation Micron buck-boost Group A listing (current JH number, weight, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eCross reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicron (old)\u003c\/td\u003e\n\u003ctd\u003eJ750A1EB1A02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcme\u003c\/td\u003e\n\u003ctd\u003eT181059\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton Cutler-Hammer\u003c\/td\u003e\n\u003ctd\u003eS10N06P76P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHevi-Duty\u003c\/td\u003e\n\u003ctd\u003eHS20F750B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPC\u003c\/td\u003e\n\u003ctd\u003eK1XGF16-0.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003ctd\u003e9T51B0129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPS (Hammond Power Solutions)\u003c\/td\u003e\n\u003ctd\u003eQC75ESCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJefferson\u003c\/td\u003e\n\u003ctd\u003e416-1241-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003ctd\u003e750SV46F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003cp\u003eIn buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 16 or 32 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y\/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.\u003c\/p\u003e\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat replaces Micron J750A1EB1A02?\u003c\/strong\u003e\u003cbr\u003eJH750A1EB1A15. Same Group A, 120 x 240 V primary, 16\/32 V secondary, 750 VA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Micron part replaces Acme T181059?\u003c\/strong\u003e\u003cbr\u003eJH750A1EB1A15, 750 VA, Group A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much load can a 750 VA buck-boost carry?\u003c\/strong\u003e\u003cbr\u003eAbout 23.4 A with the 32 V connection, or 46.8 A with the 16 V connection. Send the line volts, load volts and load amps and we check it.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/micron-control-transformers-by-kva\"\u003eMicron control transformers by kVA\u003c\/a\u003e · \u003ca href=\"\/collections\/micron\"\u003eMicron\u003c\/a\u003e · \u003ca href=\"\/collections\/buck-boost-transformers\"\u003eBuck-boost transformers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH750A1EB1A15\" class=\"aci-btn\"\u003eRequest a Quote for JH750A1EB1A15\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Micron Industries","offers":[{"title":"Default Title","offer_id":67567218295074,"sku":"JH750A1EB1A15","price":0.0,"currency_code":"USD","in_stock":true}]},{"product_id":"micron-jh100a1kc1a14-100va-buck-boost-transformer-group-b","title":"JH100A1KC1A14 Micron 100 VA Buck-Boost Transformer, Group B, 240x480V to 24\/48V (replaces J100A1KC1A01)","description":"\u003cstyle\u003e.aci-bb table{width:100%;border-collapse:collapse;margin:1em 0}.aci-bb td{padding:6px 10px;border:1px solid #ddd;color:#1a1a1a !important}.aci-bb th{padding:6px 10px;border:1px solid #ccc;text-align:left;background:#1F3864 !important;color:#ffffff !important}.aci-bb a{color:#1F3864 !important;font-weight:600}.aci-bb .aci-legal{color:#666 !important}.aci-bb a.aci-btn{display:inline-block;background:#1F3864 !important;color:#ffffff !important;padding:12px 22px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 10px 10px 0}.aci-bb a.aci-sec{background:#ffffff !important;color:#1F3864 !important;border:2px solid #1F3864;padding:10px 20px}\u003c\/style\u003e\n\u003cdiv class=\"aci-bb\"\u003e\n\u003cp\u003e\u003cstrong\u003eMicron JH100A1KC1A14 is a 100 VA Group B buck-boost transformer: 240 x 480 V primary, 24\/48 V secondary, single phase, 600 V class.\u003c\/strong\u003e It is the current number for the old Micron J100A1KC1A01. It crosses to Acme T181062 and Square D 100SV82A.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH100A1KC1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH100A1KC1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eJH100A1KC1A14 specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJH100A1KC1A14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces Micron number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ100A1KC1A01 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicron Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuck-boost transformer, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 x 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\/48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 48 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A max (VA \/ 48 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 24 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.1 A max (VA \/ 24 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year (Micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: FactoryMation Micron buck-boost Group B listing (current JH number, weight, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eCross reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicron (old)\u003c\/td\u003e\n\u003ctd\u003eJ100A1KC1A01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcme\u003c\/td\u003e\n\u003ctd\u003eT181062\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton Cutler-Hammer\u003c\/td\u003e\n\u003ctd\u003eS20N08A82N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPC\u003c\/td\u003e\n\u003ctd\u003eK2XGF24-0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003ctd\u003e9T51B0204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPS (Hammond Power Solutions)\u003c\/td\u003e\n\u003ctd\u003eQC10DTCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJefferson\u003c\/td\u003e\n\u003ctd\u003e416-1401-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003ctd\u003e100SV82A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003cp\u003eIn buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 24 or 48 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y\/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.\u003c\/p\u003e\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat replaces Micron J100A1KC1A01?\u003c\/strong\u003e\u003cbr\u003eJH100A1KC1A14. Same Group B, 240 x 480 V primary, 24\/48 V secondary, 100 VA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Micron part replaces Acme T181062?\u003c\/strong\u003e\u003cbr\u003eJH100A1KC1A14, 100 VA, Group B.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much load can a 100 VA buck-boost carry?\u003c\/strong\u003e\u003cbr\u003eAbout 2 A with the 48 V connection, or 4.1 A with the 24 V connection. Send the line volts, load volts and load amps and we check it.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/micron-control-transformers-by-kva\"\u003eMicron control transformers by kVA\u003c\/a\u003e · \u003ca href=\"\/collections\/micron\"\u003eMicron\u003c\/a\u003e · \u003ca href=\"\/collections\/buck-boost-transformers\"\u003eBuck-boost transformers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH100A1KC1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH100A1KC1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Micron Industries","offers":[{"title":"Default Title","offer_id":67567218327842,"sku":"JH100A1KC1A14","price":0.0,"currency_code":"USD","in_stock":true}]},{"product_id":"micron-jh1x5k1kc1a15-1-5kva-buck-boost-transformer-group-b","title":"JH1X5K1KC1A15 Micron 1.5 kVA Buck-Boost Transformer, Group B, 240x480V to 24\/48V (replaces J1X5K1KC1A02)","description":"\u003cstyle\u003e.aci-bb table{width:100%;border-collapse:collapse;margin:1em 0}.aci-bb td{padding:6px 10px;border:1px solid #ddd;color:#1a1a1a !important}.aci-bb th{padding:6px 10px;border:1px solid #ccc;text-align:left;background:#1F3864 !important;color:#ffffff !important}.aci-bb a{color:#1F3864 !important;font-weight:600}.aci-bb .aci-legal{color:#666 !important}.aci-bb a.aci-btn{display:inline-block;background:#1F3864 !important;color:#ffffff !important;padding:12px 22px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 10px 10px 0}.aci-bb a.aci-sec{background:#ffffff !important;color:#1F3864 !important;border:2px solid #1F3864;padding:10px 20px}\u003c\/style\u003e\n\u003cdiv class=\"aci-bb\"\u003e\n\u003cp\u003e\u003cstrong\u003eMicron JH1X5K1KC1A15 is a 1.5 kVA Group B buck-boost transformer: 240 x 480 V primary, 24\/48 V secondary, single phase, 600 V class.\u003c\/strong\u003e It is the current number for the old Micron J1X5K1KC1A02. It crosses to Acme T137921 and Square D 1.5S82F.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH1X5K1KC1A15\" class=\"aci-btn\"\u003eRequest a Quote for JH1X5K1KC1A15\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eJH1X5K1KC1A15 specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJH1X5K1KC1A15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces Micron number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ1X5K1KC1A02 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicron Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuck-boost transformer, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 x 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\/48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 48 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.2 A max (VA \/ 48 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 24 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.5 A max (VA \/ 24 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year (Micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: FactoryMation Micron buck-boost Group B listing (current JH number, weight, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eCross reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicron (old)\u003c\/td\u003e\n\u003ctd\u003eJ1X5K1KC1A02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcme\u003c\/td\u003e\n\u003ctd\u003eT137921\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton Cutler-Hammer\u003c\/td\u003e\n\u003ctd\u003eS20N08P16P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHevi-Duty\u003c\/td\u003e\n\u003ctd\u003eHS22F1.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPC\u003c\/td\u003e\n\u003ctd\u003eK2XGF24-1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003ctd\u003e9T51B0211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPS (Hammond Power Solutions)\u003c\/td\u003e\n\u003ctd\u003eQ1C5DTCF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJefferson\u003c\/td\u003e\n\u003ctd\u003e416-1461-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003ctd\u003e1.5S82F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003cp\u003eIn buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 24 or 48 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y\/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.\u003c\/p\u003e\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat replaces Micron J1X5K1KC1A02?\u003c\/strong\u003e\u003cbr\u003eJH1X5K1KC1A15. Same Group B, 240 x 480 V primary, 24\/48 V secondary, 1.5 kVA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Micron part replaces Acme T137921?\u003c\/strong\u003e\u003cbr\u003eJH1X5K1KC1A15, 1.5 kVA, Group B.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much load can a 1.5 kVA buck-boost carry?\u003c\/strong\u003e\u003cbr\u003eAbout 31.2 A with the 48 V connection, or 62.5 A with the 24 V connection. Send the line volts, load volts and load amps and we check it.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/micron-control-transformers-by-kva\"\u003eMicron control transformers by kVA\u003c\/a\u003e · \u003ca href=\"\/collections\/micron\"\u003eMicron\u003c\/a\u003e · \u003ca href=\"\/collections\/buck-boost-transformers\"\u003eBuck-boost transformers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH1X5K1KC1A15\" class=\"aci-btn\"\u003eRequest a Quote for JH1X5K1KC1A15\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Micron Industries","offers":[{"title":"Default Title","offer_id":67567218360610,"sku":"JH1X5K1KC1A15","price":0.0,"currency_code":"USD","in_stock":true}]},{"product_id":"micron-jh001k1eb1a15-1kva-buck-boost-transformer-group-a","title":"JH001K1EB1A15 Micron 1 kVA Buck-Boost Transformer, Group A, 120x240V to 16\/32V (replaces J001K1EB1A02)","description":"\u003cstyle\u003e.aci-bb table{width:100%;border-collapse:collapse;margin:1em 0}.aci-bb td{padding:6px 10px;border:1px solid #ddd;color:#1a1a1a !important}.aci-bb th{padding:6px 10px;border:1px solid #ccc;text-align:left;background:#1F3864 !important;color:#ffffff !important}.aci-bb a{color:#1F3864 !important;font-weight:600}.aci-bb .aci-legal{color:#666 !important}.aci-bb a.aci-btn{display:inline-block;background:#1F3864 !important;color:#ffffff !important;padding:12px 22px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 10px 10px 0}.aci-bb a.aci-sec{background:#ffffff !important;color:#1F3864 !important;border:2px solid #1F3864;padding:10px 20px}\u003c\/style\u003e\n\u003cdiv class=\"aci-bb\"\u003e\n\u003cp\u003e\u003cstrong\u003eMicron JH001K1EB1A15 is a 1 kVA Group A buck-boost transformer: 120 x 240 V primary, 16\/32 V secondary, single phase, 600 V class.\u003c\/strong\u003e It is the current number for the old Micron J001K1EB1A02. It crosses to Acme T113073 and Square D 1S46F.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH001K1EB1A15\" class=\"aci-btn\"\u003eRequest a Quote for JH001K1EB1A15\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eJH001K1EB1A15 specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJH001K1EB1A15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces Micron number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ001K1EB1A02 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicron Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuck-boost transformer, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 x 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\/32 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 32 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.2 A max (VA \/ 32 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 16 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.5 A max (VA \/ 16 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year (Micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: FactoryMation Micron buck-boost Group A listing (current JH number, weight, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eCross reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicron (old)\u003c\/td\u003e\n\u003ctd\u003eJ001K1EB1A02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcme\u003c\/td\u003e\n\u003ctd\u003eT113073\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton Cutler-Hammer\u003c\/td\u003e\n\u003ctd\u003eS10N06P01P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHevi-Duty\u003c\/td\u003e\n\u003ctd\u003eHS20F1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPC\u003c\/td\u003e\n\u003ctd\u003eK1XGF16-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003ctd\u003e9T51B0130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPS (Hammond Power Solutions)\u003c\/td\u003e\n\u003ctd\u003eQ1C0ESCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJefferson\u003c\/td\u003e\n\u003ctd\u003e416-1251-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003ctd\u003e1S46F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003cp\u003eIn buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 16 or 32 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y\/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.\u003c\/p\u003e\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat replaces Micron J001K1EB1A02?\u003c\/strong\u003e\u003cbr\u003eJH001K1EB1A15. Same Group A, 120 x 240 V primary, 16\/32 V secondary, 1 kVA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Micron part replaces Acme T113073?\u003c\/strong\u003e\u003cbr\u003eJH001K1EB1A15, 1 kVA, Group A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much load can a 1 kVA buck-boost carry?\u003c\/strong\u003e\u003cbr\u003eAbout 31.2 A with the 32 V connection, or 62.5 A with the 16 V connection. Send the line volts, load volts and load amps and we check it.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/micron-control-transformers-by-kva\"\u003eMicron control transformers by kVA\u003c\/a\u003e · \u003ca href=\"\/collections\/micron\"\u003eMicron\u003c\/a\u003e · \u003ca href=\"\/collections\/buck-boost-transformers\"\u003eBuck-boost transformers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH001K1EB1A15\" class=\"aci-btn\"\u003eRequest a Quote for JH001K1EB1A15\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Micron Industries","offers":[{"title":"Default Title","offer_id":67567218983202,"sku":"JH001K1EB1A15","price":0.0,"currency_code":"USD","in_stock":true}]},{"product_id":"micron-jh150a1kc1a14-150va-buck-boost-transformer-group-b","title":"JH150A1KC1A14 Micron 150 VA Buck-Boost Transformer, Group B, 240x480V to 24\/48V (replaces J150A1KC1A01)","description":"\u003cstyle\u003e.aci-bb table{width:100%;border-collapse:collapse;margin:1em 0}.aci-bb td{padding:6px 10px;border:1px solid #ddd;color:#1a1a1a !important}.aci-bb th{padding:6px 10px;border:1px solid #ccc;text-align:left;background:#1F3864 !important;color:#ffffff !important}.aci-bb a{color:#1F3864 !important;font-weight:600}.aci-bb .aci-legal{color:#666 !important}.aci-bb a.aci-btn{display:inline-block;background:#1F3864 !important;color:#ffffff !important;padding:12px 22px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 10px 10px 0}.aci-bb a.aci-sec{background:#ffffff !important;color:#1F3864 !important;border:2px solid #1F3864;padding:10px 20px}\u003c\/style\u003e\n\u003cdiv class=\"aci-bb\"\u003e\n\u003cp\u003e\u003cstrong\u003eMicron JH150A1KC1A14 is a 150 VA Group B buck-boost transformer: 240 x 480 V primary, 24\/48 V secondary, single phase, 600 V class.\u003c\/strong\u003e It is the current number for the old Micron J150A1KC1A01. It crosses to Acme T181063 and Square D 150SV82A.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH150A1KC1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH150A1KC1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eJH150A1KC1A14 specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJH150A1KC1A14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces Micron number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ150A1KC1A01 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicron Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuck-boost transformer, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 x 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\/48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 48 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.1 A max (VA \/ 48 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 24 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.2 A max (VA \/ 24 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year (Micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: FactoryMation Micron buck-boost Group B listing (current JH number, weight, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eCross reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicron (old)\u003c\/td\u003e\n\u003ctd\u003eJ150A1KC1A01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcme\u003c\/td\u003e\n\u003ctd\u003eT181063\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton Cutler-Hammer\u003c\/td\u003e\n\u003ctd\u003eS20N08A83N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHevi-Duty\u003c\/td\u003e\n\u003ctd\u003eHS22B150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPC\u003c\/td\u003e\n\u003ctd\u003eK2XGF24-0.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003ctd\u003e9T51B0205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPS (Hammond Power Solutions)\u003c\/td\u003e\n\u003ctd\u003eQC15DTCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJefferson\u003c\/td\u003e\n\u003ctd\u003e416-1411-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003ctd\u003e150SV82A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003cp\u003eIn buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 24 or 48 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y\/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.\u003c\/p\u003e\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat replaces Micron J150A1KC1A01?\u003c\/strong\u003e\u003cbr\u003eJH150A1KC1A14. Same Group B, 240 x 480 V primary, 24\/48 V secondary, 150 VA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Micron part replaces Acme T181063?\u003c\/strong\u003e\u003cbr\u003eJH150A1KC1A14, 150 VA, Group B.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much load can a 150 VA buck-boost carry?\u003c\/strong\u003e\u003cbr\u003eAbout 3.1 A with the 48 V connection, or 6.2 A with the 24 V connection. Send the line volts, load volts and load amps and we check it.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/micron-control-transformers-by-kva\"\u003eMicron control transformers by kVA\u003c\/a\u003e · \u003ca href=\"\/collections\/micron\"\u003eMicron\u003c\/a\u003e · \u003ca href=\"\/collections\/buck-boost-transformers\"\u003eBuck-boost transformers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH150A1KC1A14\" class=\"aci-btn\"\u003eRequest a Quote for JH150A1KC1A14\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Micron Industries","offers":[{"title":"Default Title","offer_id":67567219048738,"sku":"JH150A1KC1A14","price":0.0,"currency_code":"USD","in_stock":true}]},{"product_id":"micron-jh002k1kc1a15-2kva-buck-boost-transformer-group-b","title":"JH002K1KC1A15 Micron 2 kVA Buck-Boost Transformer, Group B, 240x480V to 24\/48V (replaces J002K1KC1A02)","description":"\u003cstyle\u003e.aci-bb table{width:100%;border-collapse:collapse;margin:1em 0}.aci-bb td{padding:6px 10px;border:1px solid #ddd;color:#1a1a1a !important}.aci-bb th{padding:6px 10px;border:1px solid #ccc;text-align:left;background:#1F3864 !important;color:#ffffff !important}.aci-bb a{color:#1F3864 !important;font-weight:600}.aci-bb .aci-legal{color:#666 !important}.aci-bb a.aci-btn{display:inline-block;background:#1F3864 !important;color:#ffffff !important;padding:12px 22px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 10px 10px 0}.aci-bb a.aci-sec{background:#ffffff !important;color:#1F3864 !important;border:2px solid #1F3864;padding:10px 20px}\u003c\/style\u003e\n\u003cdiv class=\"aci-bb\"\u003e\n\u003cp\u003e\u003cstrong\u003eMicron JH002K1KC1A15 is a 2 kVA Group B buck-boost transformer: 240 x 480 V primary, 24\/48 V secondary, single phase, 600 V class.\u003c\/strong\u003e It is the current number for the old Micron J002K1KC1A02. It crosses to Acme T137922 and Square D 2S82F.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH002K1KC1A15\" class=\"aci-btn\"\u003eRequest a Quote for JH002K1KC1A15\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eJH002K1KC1A15 specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJH002K1KC1A15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces Micron number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ002K1KC1A02 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicron Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuck-boost transformer, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 x 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\/48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 48 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41.6 A max (VA \/ 48 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 24 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e83.3 A max (VA \/ 24 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year (Micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: FactoryMation Micron buck-boost Group B listing (current JH number, weight, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eCross reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicron (old)\u003c\/td\u003e\n\u003ctd\u003eJ002K1KC1A02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcme\u003c\/td\u003e\n\u003ctd\u003eT137922\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton Cutler-Hammer\u003c\/td\u003e\n\u003ctd\u003eS20N08P02P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHevi-Duty\u003c\/td\u003e\n\u003ctd\u003eHS22F2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPC\u003c\/td\u003e\n\u003ctd\u003eK2XGF24-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003ctd\u003e9T51B0212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPS (Hammond Power Solutions)\u003c\/td\u003e\n\u003ctd\u003eQ002DTCF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJefferson\u003c\/td\u003e\n\u003ctd\u003e416-1471-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003ctd\u003e2S82F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003cp\u003eIn buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 24 or 48 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y\/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.\u003c\/p\u003e\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat replaces Micron J002K1KC1A02?\u003c\/strong\u003e\u003cbr\u003eJH002K1KC1A15. Same Group B, 240 x 480 V primary, 24\/48 V secondary, 2 kVA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Micron part replaces Acme T137922?\u003c\/strong\u003e\u003cbr\u003eJH002K1KC1A15, 2 kVA, Group B.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much load can a 2 kVA buck-boost carry?\u003c\/strong\u003e\u003cbr\u003eAbout 41.6 A with the 48 V connection, or 83.3 A with the 24 V connection. Send the line volts, load volts and load amps and we check it.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/micron-control-transformers-by-kva\"\u003eMicron control transformers by kVA\u003c\/a\u003e · \u003ca href=\"\/collections\/micron\"\u003eMicron\u003c\/a\u003e · \u003ca href=\"\/collections\/buck-boost-transformers\"\u003eBuck-boost transformers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH002K1KC1A15\" class=\"aci-btn\"\u003eRequest a Quote for JH002K1KC1A15\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Micron Industries","offers":[{"title":"Default Title","offer_id":67567219114274,"sku":"JH002K1KC1A15","price":0.0,"currency_code":"USD","in_stock":true}]},{"product_id":"micron-jh1x5k1eb1a15-1-5kva-buck-boost-transformer-group-a","title":"JH1X5K1EB1A15 Micron 1.5 kVA Buck-Boost Transformer, Group A, 120x240V to 16\/32V (replaces J1X5K1EB1A02)","description":"\u003cstyle\u003e.aci-bb table{width:100%;border-collapse:collapse;margin:1em 0}.aci-bb td{padding:6px 10px;border:1px solid #ddd;color:#1a1a1a !important}.aci-bb th{padding:6px 10px;border:1px solid #ccc;text-align:left;background:#1F3864 !important;color:#ffffff !important}.aci-bb a{color:#1F3864 !important;font-weight:600}.aci-bb .aci-legal{color:#666 !important}.aci-bb a.aci-btn{display:inline-block;background:#1F3864 !important;color:#ffffff !important;padding:12px 22px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 10px 10px 0}.aci-bb a.aci-sec{background:#ffffff !important;color:#1F3864 !important;border:2px solid #1F3864;padding:10px 20px}\u003c\/style\u003e\n\u003cdiv class=\"aci-bb\"\u003e\n\u003cp\u003e\u003cstrong\u003eMicron JH1X5K1EB1A15 is a 1.5 kVA Group A buck-boost transformer: 120 x 240 V primary, 16\/32 V secondary, single phase, 600 V class.\u003c\/strong\u003e It is the current number for the old Micron J1X5K1EB1A02. It crosses to Acme T113074 and Square D 1.5S46F.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH1X5K1EB1A15\" class=\"aci-btn\"\u003eRequest a Quote for JH1X5K1EB1A15\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eJH1X5K1EB1A15 specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJH1X5K1EB1A15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces Micron number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ1X5K1EB1A02 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicron Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuck-boost transformer, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 x 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\/32 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 32 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e46.8 A max (VA \/ 32 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad amps, boost or buck at 16 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93.7 A max (VA \/ 16 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year (Micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: FactoryMation Micron buck-boost Group A listing (current JH number, weight, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eCross reference\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicron (old)\u003c\/td\u003e\n\u003ctd\u003eJ1X5K1EB1A02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcme\u003c\/td\u003e\n\u003ctd\u003eT113074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEaton Cutler-Hammer\u003c\/td\u003e\n\u003ctd\u003eS10N06P16P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHevi-Duty\u003c\/td\u003e\n\u003ctd\u003eHS20F1.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPC\u003c\/td\u003e\n\u003ctd\u003eK1XGF16-1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003ctd\u003e9T51B0131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHPS (Hammond Power Solutions)\u003c\/td\u003e\n\u003ctd\u003eQ1C5ESCF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJefferson\u003c\/td\u003e\n\u003ctd\u003e416-1261-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003ctd\u003e1.5S46F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"aci-legal\"\u003e\u003csmall\u003eSource: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003cp\u003eIn buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 16 or 32 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y\/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.\u003c\/p\u003e\n\u003ch2\u003eCommon questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat replaces Micron J1X5K1EB1A02?\u003c\/strong\u003e\u003cbr\u003eJH1X5K1EB1A15. Same Group A, 120 x 240 V primary, 16\/32 V secondary, 1.5 kVA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Micron part replaces Acme T113074?\u003c\/strong\u003e\u003cbr\u003eJH1X5K1EB1A15, 1.5 kVA, Group A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much load can a 1.5 kVA buck-boost carry?\u003c\/strong\u003e\u003cbr\u003eAbout 46.8 A with the 32 V connection, or 93.7 A with the 16 V connection. Send the line volts, load volts and load amps and we check it.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/pages\/buck-boost-transformer-sizing-cross-reference\"\u003eBuck-boost sizing and full cross reference\u003c\/a\u003e · \u003ca href=\"\/pages\/micron-control-transformers-by-kva\"\u003eMicron control transformers by kVA\u003c\/a\u003e · \u003ca href=\"\/collections\/micron\"\u003eMicron\u003c\/a\u003e · \u003ca href=\"\/collections\/buck-boost-transformers\"\u003eBuck-boost transformers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/request-a-quote?part=JH1X5K1EB1A15\" class=\"aci-btn\"\u003eRequest a Quote for JH1X5K1EB1A15\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" class=\"aci-btn aci-sec\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Micron Industries","offers":[{"title":"Default Title","offer_id":67567219147042,"sku":"JH1X5K1EB1A15","price":0.0,"currency_code":"USD","in_stock":true}]}],"url":"https:\/\/aci-automation.com\/collections\/buck-boost-transformers.oembed","provider":"Applied Control","version":"1.0","type":"link"}