{"title":"Citel Surge Protection","description":"\u003cp\u003eCitel Type 1, Type 2 and Type 4CA surge protective devices for AC power, DC power, dataline and RF circuits. Applied Control is the Citel representative for Michigan and Indiana. Send a part number or a one-line for a same day quote.\u003c\/p\u003e","products":[{"product_id":"citel-dac101us-210","title":"DAC101US-210 Citel Type 1 Surge Protector, 210 V 1PH, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC101US-210 is a Type 1 surge protective device for 210 V 1PH circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (File Number E326289). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eSurge protection device for single-phase AC power with visual fault indicator, remote contacts, and pluggable\/replaceable modules.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC101US-210 specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC101US-210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110079\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 5th Edition TYPE 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL Listed (File Number E326289)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e210V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eSingle phase, 1 wire + ground (L-N mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e210V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e700V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e0.29 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC101US-210. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3314968\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC101US-210 (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52623853027618,"sku":"DAC101US-210","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513472.webp?v=1790319372"},{"product_id":"citel-dac101us-275","title":"DAC101US-275 Citel Type 1 Surge Protector, 220 V 1PH, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC101US-275 is a Type 1 surge protective device for 220 V 1PH circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (File Number E326289, Categories VZCA, VZCA7). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eSingle phase, 220V AC surge protective device with pluggable\/replaceable modules, visual fault indicator, remote contacts, and 10-year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC101US-275 specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC101US-275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 5th Edition Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL Listed (File Number E326289, Categories VZCA, VZCA7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e220V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eSingle phase, 1 wire + ground (L-N mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e275V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e900V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e0.29 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC101US-275. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3003708\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC101US-275 (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52623856927010,"sku":"DAC101US-275","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3514595.webp?v=1790319528"},{"product_id":"citel-dac102us-120s","title":"DAC102US-120S Citel Type 1 Surge Protector, 120 V 1PH, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC102US-120S is a Type 1 surge protective device for 120 V 1PH circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL1449 Type 1 Listed. Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eSurge protection device with pluggable\/replaceable modules, visual fault indicator, remote contacts, and 10-year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC102US-120S specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC102US-120S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e120V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1 Phase, 2 Wire + Ground (1PH, 2W+G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-N, L-G, N-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e210\/360\/150 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e700\/1000\/600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1.20 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC102US-120S. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3314965\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC102US-120S (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52623856959778,"sku":"DAC102US-120S","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513488.webp?v=1790319529"},{"product_id":"citel-dac102us-120s-g","title":"DAC102US-120S\/G Citel Type 1 Surge Protector, 120 V 1PH, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC102US-120S\/G is a Type 1 surge protective device for 120 V 1PH circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL1449 Type 1 Listed. Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eSurge protective device with pluggable\/replaceable modules, visual fault indicator, remote contacts, and 10-year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC102US-120S\/G specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC102US-120S\/G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e120V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eSingle phase, 2 wires plus ground (1PH, 2W+G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-N, L-G, N-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e210\/210\/277 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e800\/1500\/1200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN RAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1.20 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC102US-120S\/G. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3177190\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC102US-120S\/G (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52623857025314,"sku":"DAC102US-120S\/G","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513500.webp?v=1790319530"},{"product_id":"citel-dac102us-240t-nn","title":"DAC102US-240T\/NN Citel Type 1 Surge Protector, 240\/480 V 1PH Split Phase, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC102US-240T\/NN is a Type 1 surge protective device for 240\/480 V 1PH split phase circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (File Number E326289). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eSurge protection device with pluggable\/replaceable modules, visual fault indicator, remote contacts, and 10-year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC102US-240T\/NN specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC102US-240T\/NN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 5th edition Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL Listed (File Number E326289)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e240\/480, 120\/240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eSingle-phase, 2-pole, 2W+G, Single\/Split Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e770\/385 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e2000\/1200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN RAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e0.60 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC102US-240T\/NN. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3177194\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC102US-240T\/NN (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52623857058082,"sku":"DAC102US-240T\/NN","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513490.webp?v=1790319531"},{"product_id":"citel-dac103us-120t","title":"DAC103US-120T Citel Type 1 Surge Protector, 120\/240 V 1PH Split Phase, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC103US-120T is a Type 1 surge protective device for 120\/240 V 1PH split phase circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL1449 Type 1 Listed. Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eSurge protective device featuring pluggable\/replaceable modules with visual fault indicator and remote contacts.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC103US-120T specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC103US-120T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e120\/240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1 Phase, 2 Wire + Ground, Split Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-N, L-G, N-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e420\/210\/360\/150 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1200\/700\/1000\/600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN RAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e0.83 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC103US-120T. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3314972\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC103US-120T (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52623861285154,"sku":"DAC103US-120T","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513515.webp?v=1790319735"},{"product_id":"citel-dac103us-120t-g","title":"DAC103US-120T\/G Citel Type 1 Surge Protector, 120\/240 V 1PH Split Phase, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC103US-120T\/G is a Type 1 surge protective device for 120\/240 V 1PH split phase circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (File E326289). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eThree-pole, three-wire plus ground surge protective device for split-phase applications with pluggable\/replaceable modules and visual fault indicator with remote contacts.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC103US-120T\/G specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC103US-120T\/G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 5th edition Type 1 SPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL Listed (File E326289)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e120\/240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1 phase, 3 poles, 3W+G, Split Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-N, L-G, N-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e420\/210\/210\/277 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1200\/700\/1500\/1200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN RAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e0.83 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC103US-120T\/G. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3314973\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC103US-120T\/G (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52623861317922,"sku":"DAC103US-120T\/G","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513513.webp?v=1790319736"},{"product_id":"citel-dac103us-277y-nn","title":"DAC103US-277Y\/NN Citel Type 1 Surge Protector, 277\/480 V 3PH Wye, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC103US-277Y\/NN is a Type 1 surge protective device for 277\/480 V 3PH wye circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL1449 Type 1 Listed. Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eSurge protective device for AC power distribution with pluggable\/replaceable modules, visual fault indicator, remote contacts, and 10-year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC103US-277Y\/NN specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC103US-277Y\/NN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110109\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e277\/480, 120\/208, 240\/415, 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3-phase, 3-wire plus ground, no neutral; wye configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e770\/385V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e2000\/1200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e0.83 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC103US-277Y\/NN. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3314978\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC103US-277Y\/NN (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52623861383458,"sku":"DAC103US-277Y\/NN","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513502.webp?v=1790319737"},{"product_id":"citel-dac104us-120y","title":"DAC104US-120Y Citel Type 1 Surge Protector, 120\/208 V 3PH Wye, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC104US-120Y is a Type 1 surge protective device for 120\/208 V 3PH wye circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL1449 Type 1 Listed. Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eSurge protection device featuring UL1449 5th edition, Type 1 SPD rating with pluggable\/replaceable modules, visual fault indicator, remote contacts, and 10-year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC104US-120Y specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC104US-120Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e120\/208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3-phase, 4-wire plus ground, Wye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-N, L-G, N-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e300\/150\/300\/150 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e900\/600\/900\/600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN RAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1.32 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC104US-120Y. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3159760\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC104US-120Y (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52623861416226,"sku":"DAC104US-120Y","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513541.webp?v=1790319738"},{"product_id":"citel-dac104us-120y-g","title":"DAC104US-120Y\/G Citel Type 1 Surge Protector, 120\/208 V 3PH Wye, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC104US-120Y\/G is a Type 1 surge protective device for 120\/208 V 3PH wye circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (File Number E326289, Category VZCA, VZCA7). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eSurge protective device featuring pluggable\/replaceable modules with visual fault indicator and remote contacts, backed by 10-year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC104US-120Y\/G specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC104US-120Y\/G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL Listed (File Number E326289, Category VZCA, VZCA7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e120\/208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3-phase, 4-wire plus ground, Wye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-N, L-G, N-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e300\/150\/150\/277 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e900\/600\/1500\/1200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN RAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1.32 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC104US-120Y\/G. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3314979\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC104US-120Y\/G (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52623861481762,"sku":"DAC104US-120Y\/G","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513535.webp?v=1790319739"},{"product_id":"citel-dac104us-240d","title":"DAC104US-240D Citel Type 1 Surge Protector, 240 V 3PH Delta, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC104US-240D is a Type 1 surge protective device for 240 V 3PH delta circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL1449 Type 1 Listed. Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eUL1449 5th edition Type 1 SPD with visual fault indicator, remote contacts, pluggable\/replaceable modules, and 10-year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC104US-240D specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC104US-240D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3-phase, 3-wire + ground, Delta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e300V \/ 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e900V \/ 900V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1.32 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC104US-240D. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3314984\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC104US-240D (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52623864529186,"sku":"DAC104US-240D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513525.webp?v=1790319923"},{"product_id":"citel-dac104us-240y","title":"DAC104US-240Y Citel Type 1 Surge Protector, 240\/415 V 3PH Wye, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC104US-240Y is a Type 1 surge protective device for 240\/415 V 3PH wye circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL1449 Type 1 Listed. Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eModular surge protective device with pluggable\/replaceable modules, visual fault indicator, and remote contacts.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC104US-240Y specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC104US-240Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e240\/415, 120\/208, 230\/400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3-phase, 4-wire plus ground, Wye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-N, L-G, N-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e640\/320\/595\/275 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1800\/1000\/1800\/900 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1.32 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC104US-240Y. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3314982\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC104US-240Y (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52623864594722,"sku":"DAC104US-240Y","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513529.webp?v=1790319924"},{"product_id":"citel-dac104us-277y","title":"DAC104US-277Y Citel Type 1 Surge Protector, 277\/480 V 3PH Wye, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC104US-277Y is a Type 1 surge protective device for 277\/480 V 3PH wye circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL1449 Type 1 Listed. Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eMulti-MOV technology, 3-phase, 4-wire plus ground wye configuration with screw terminals, DIN rail mounted, thermoplastic UL94-V0 enclosure.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC104US-277Y specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC104US-277Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110132\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e277\/480, 120\/208, 230\/400, 240\/415V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3-phase, 4-wire + ground, Wye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-N, L-G, N-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e770\/385\/705\/320V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e2000\/1200\/1800\/1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN RAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1.32 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC104US-277Y. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3003713\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC104US-277Y (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52623864627490,"sku":"DAC104US-277Y","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513543.webp?v=1790319925"},{"product_id":"citel-dac104us-277y-g","title":"DAC104US-277Y\/G Citel Type 1 Surge Protector, 277\/480 V 3PH Wye, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC104US-277Y\/G is a Type 1 surge protective device for 277\/480 V 3PH wye circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL File Number E326289. Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eSurge protective device with pluggable\/replaceable modules, visual fault indicator and remote contacts, featuring 10-year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC104US-277Y\/G specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC104US-277Y\/G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 TYPE 1 LISTED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL File Number E326289\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e277\/480, 120\/208, 230\/400, 240\/415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3-phase, 4-wire plus ground, Wye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-N, L-G, N-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e770\/385\/385\/277 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e2000\/1200\/1500\/1200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN RAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1.32 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC104US-277Y\/G. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3314986\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC104US-277Y\/G (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52623864693026,"sku":"DAC104US-277Y\/G","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513521.webp?v=1790319926"},{"product_id":"citel-dac104us-347y","title":"DAC104US-347Y Citel Type 1 Surge Protector, 347\/600 V 3PH Wye, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC104US-347Y is a Type 1 surge protective device for 347\/600 V 3PH wye circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (E326289). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eSurge protector device for 3-phase AC power with visual fault indicator, remote contacts, and pluggable\/replaceable modules.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC104US-347Y specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC104US-347Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110134\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 5th edition Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL Listed (E326289)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e347\/600, 120\/208, 230\/400, 240\/415, 277\/480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3PH, 4W+G, Wye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-N, L-G, N-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e880\/440\/825\/385V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e2500\/1200\/2000\/1200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN RAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1.32 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC104US-347Y. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3314987\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC104US-347Y (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52623864725794,"sku":"DAC104US-347Y","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513519.webp?v=1790319927"},{"product_id":"citel-dac104us-480d","title":"DAC104US-480D Citel Type 1 Surge Protector, 480 V 3PH Delta, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC104US-480D is a Type 1 surge protective device for 480 V 3PH delta circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (File E326289). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC104US-480D specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC104US-480D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110135\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eType 1 SPD, UL1449 5th edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL Listed (File E326289)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e480V, 240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3-phase, 3-wire plus ground, Delta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e550V \/ 550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1500V \/ 1500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN RAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1.32 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC104US-480D. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3159763\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC104US-480D (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52626001494306,"sku":"DAC104US-480D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513539.webp?v=1790364799"},{"product_id":"citel-dac104us-600d","title":"DAC104US-600D Citel Type 1 Surge Protector, 600 V 3PH Delta, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC104US-600D is a Type 1 surge protective device for 600 V 3PH delta circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (File: E326289). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC104US-600D specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC104US-600D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110136\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 5th edition Type 1 SPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL Listed (File: E326289)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e600V, 240V, 480V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3-phase, 3-wire + ground, Delta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e880V \/ 880V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e2500V \/ 2500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN RAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1.32 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC104US-600D. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3314988\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC104US-600D (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52626002346274,"sku":"DAC104US-600D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513517.webp?v=1790364850"},{"product_id":"citel-mds600e-480d","title":"MDS600E-480D Citel Type 1 Surge Protector, 480 V 3PH Delta, 300 kA Flange Mount","description":"\u003cp\u003eThe Citel MDS600E-480D is a Type 1 surge protective device for 480 V 3PH delta circuits, flange mount mounting, with Imax 300 kA and In 20 kA. It is UL1449 5th edition. Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eMDS600E-480D specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eMDS600E-480D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e890647\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eMDS600E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 5th edition Type 1, optional Type 2 with UL1283 Filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 5th edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3-phase, 3-wire + ground, Delta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e550V (L-L and L-G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e2000V (L-L and L-G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e300 per phase kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eFlange mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 4\/12 (Stainless Steel NEMA 4X optional), IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e14.2x6.3x16 (LxWxH-inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e17 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eAudible alarm and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eServiceable Individual Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eStandard 10-year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for MDS600E-480D. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=1369130\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for MDS600E-480D (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52626005098786,"sku":"MDS600E-480D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/2632100.webp?v=1790364900"},{"product_id":"citel-ms200-480d","title":"MS200-480D Citel Type 1 Surge Protector, 480 V 3PH Delta, 220 kA Flange Mount","description":"\u003cp\u003eThe Citel MS200-480D is a Type 1 surge protective device for 480 V 3PH delta circuits, flange mount mounting, with Imax 220 kA and In 20 kA. It is UL1449 Type 1 LISTED. Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eMulti-TMOV Technology, UL1449 Type 1 LISTED, BABA-Build America-Buy America compliant, 220kA Surge Current Rating, Visual fault indicator, audible alarm and remote contacts, 10-Year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eMS200-480D specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eMS200-480D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e890134\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eMS200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1 LISTED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3-phase, 3-wire + ground, Delta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1100V (L-L), 550V (L-G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3000V (L-L), 1800V (L-G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e220 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eFlange mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 3R,4, 12 (IP65)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e% of protection present LED, audible alarm and remote contacts. Optional surge counter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for MS200-480D. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=2178360\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for MS200-480D (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52626006180130,"sku":"MS200-480D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3968425.webp?v=1790364948"},{"product_id":"citel-mp100-277y","title":"MP100-277Y Citel Type 1 Surge Protector, 277\/480 V 3PH Wye, 132 kA Flange Mount","description":"\u003cp\u003eThe Citel MP100-277Y is a Type 1 surge protective device for 277\/480 V 3PH wye circuits, flange mount mounting, with Imax 132 kA and In 20 kA. It is UL1449 Type 1 Listed. Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eMulti-TMOV Technology, UL1449 Type 1 LISTED, 132kA Imax Surge Current Rating, Visual fault indicator, 10-Year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eMP100-277Y specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eMP100-277Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e891805\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eMP100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e277\/480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3 Phase, 4 Wire + Ground, Wye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-N, L-G, N-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e640\/320\/320\/320V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1800\/1000\/1200\/1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e132 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eFlange Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 4X (IP67)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to 85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for MP100-277Y. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=2177477\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for MP100-277Y (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52626014175522,"sku":"MP100-277Y","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/2611492.webp?v=1790364996"},{"product_id":"citel-ds240s-120-ex","title":"DS240S-120-Ex Citel Type 4CA Surge Protector, 120 V 1PH, 40 kA DIN Rail","description":"\u003cp\u003eThe Citel DS240S-120-Ex is a Type 4CA surge protective device for 120 V 1PH circuits, DIN rail mounting, with Imax 40 kA and In 20 kA. It is UL1449 5th Ed. \u0026amp; UL121201 Class I, Division 2, Groups A, B, C \u0026amp; D. Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eSurge protection device with MOV technology, UL1449 Type 4CA rating, visual fault indicator, remote contacts, and 10-year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDS240S-120-Ex specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDS240S-120-Ex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e897006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDS240S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 5th Edition TYPE 4CA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 5th Ed. \u0026amp; UL121201 Class I, Division 2, Groups A, B, C \u0026amp; D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e120 Vac (Network: 120\/208 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eSingle Phase, 2W+G (L\/PE and N\/PE connection modes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eCommon mode (L-L, L-N, L-G, N-G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e300\/150\/300\/150 V (L-L, L-N, L-G, N-G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e0.6 kV (Residual Voltage at 5 kA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e40 (per pole); 80 total kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN rail 35 mm (EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eIP20 \/ NEMA 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e0.30 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDSM240-120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40\/+85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DS240S-120-Ex. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=2765180\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DS240S-120-Ex (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52626020630818,"sku":"DS240S-120-Ex","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/1523089.webp?v=1790365047"},{"product_id":"citel-ds240s-230-ex","title":"DS240S-230-Ex Citel Type 4CA Surge Protector, 230 V 1PH, 40 kA DIN Rail","description":"\u003cp\u003eThe Citel DS240S-230-Ex is a Type 4CA surge protective device for 230 V 1PH circuits, DIN rail mounting, with Imax 40 kA and In 20 kA. It is UL121201 (Class I, Division 2, Groups A, B, C \u0026amp; D). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eUL121201 Hazardous Locations, MOV Technology, UL1449 Type 4CA, 40kA Surge Current Rating, Visual fault indicator and remote contacts, 10-Year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDS240S-230-Ex specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDS240S-230-Ex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e897008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDS240S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 5th Edition TYPE 4CA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL121201 (Class I, Division 2, Groups A, B, C \u0026amp; D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e230 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eSingle Phase, 2-wire + ground (L\/PE and N\/PE); Common mode protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-G, L-N, N-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e510V (L-L), 255V (L-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e0.9 kV (Residual Voltage @ 5kA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e40 per pole; 80 total kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDin Rail (35mm symmetrical, EN 60715)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eIP20 \/ NEMA 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e90mm L x 67mm H x 18mm W (3.54\" x 2.63\" x 0.71\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e0.30 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eModule (spare part available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DS240S-230-Ex. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=2765200\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DS240S-230-Ex (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52626029510946,"sku":"DS240S-230-Ex","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/1523095.webp?v=1790365098"},{"product_id":"citel-ms100-120y","title":"MS100-120Y Citel Type 1 Surge Protector, 120\/208 V 3PH Wye, 132 kA Flange Mount","description":"\u003cp\u003eThe Citel MS100-120Y is a Type 1 surge protective device for 120\/208 V 3PH wye circuits, flange mount mounting, with Imax 132 kA and In 20 kA. It is UL1449 Type 1 LISTED. Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eMulti-TMOV Technology surge protective device with visual fault indicator, audible alarm and remote contacts; 10-Year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eMS100-120Y specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eMS100-120Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e890119\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eMS100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1 LISTED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e120\/208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3 phase, 4 wire + ground, Wye (3Y)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-N, L-G, N-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e300\/150\/150\/150V (L-L, L-N, L-G, N-G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1000\/700\/700\/700V (L-L, L-N, L-G, N-G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e132 per phase kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eFlange mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 3R, 4, 12 (IP65)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual fault indicator, audible alarm and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for MS100-120Y. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=2178730\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for MS100-120Y (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52626039996706,"sku":"MS100-120Y","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3968425_d25fa8f8-3065-472b-b808-fdf895f64bdc.webp?v=1790365148"},{"product_id":"citel-mp100-120y","title":"MP100-120Y Citel Type 1 Surge Protector, 120\/208 V 3PH Wye, 132 kA Flange Mount","description":"\u003cp\u003eThe Citel MP100-120Y is a Type 1 surge protective device for 120\/208 V 3PH wye circuits, flange mount mounting, with Imax 132 kA and In 20 kA. It is UL1449 TYPE 1 LISTED. Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eMulti-TMOV Technology, UL1449 Type 1 LISTED, 132kA Imax Surge Current Rating, Visual fault indicator, 10-Year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eMP100-120Y specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eMP100-120Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e891804\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eMP100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 TYPE 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 TYPE 1 LISTED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e120\/208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3PH, 4W+G, Wye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-N, L-G, N-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e300\/150\/150\/150V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1000\/700\/700\/700V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e132 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eFLANGE MOUNT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 4X (IP67)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to 85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for MP100-120Y. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=2177383\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for MP100-120Y (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52626048581922,"sku":"MP100-120Y","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/2611492_8d25f649-9c04-4224-9399-5fbe1358e4f2.webp?v=1790365196"},{"product_id":"citel-dac101us-320","title":"DAC101US-320 Citel Type 1 Surge Protector, 235 V 1PH, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC101US-320 is a Type 1 surge protective device for 235 V 1PH circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (File Number E326289). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eSurge protection device featuring UL1449 5th edition Type 1 certification with maximum current handling of 100kA and nominal discharge current of 20kA, designed for modular DIN rail mounting.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC101US-320 specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC101US-320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110081\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 5th Edition TYPE 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL Listed (File Number E326289)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e235V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1PH, 1W+G, Single Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e320V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e0.29 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC101US-320. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3314969\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC101US-320 (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":67388259041570,"sku":"DAC101US-320","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513477.webp?v=1790468633"},{"product_id":"citel-dac101us-385","title":"DAC101US-385 Citel Type 1 Surge Protector, 345 V 1PH, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC101US-385 is a Type 1 surge protective device for 345 V 1PH circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (File Number E326289). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eUL1449 5th edition, Type 1 SPD, Imax-100kA, In-20kA, Visual fault indicator and remote contacts, Pluggable\/Replaceable Modules, 10-Year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC101US-385 specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC101US-385\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110082\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 5th Edition TYPE 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL Listed (File Number E326289)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e345V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1PH, 1W+G, Single Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e385V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e0.29 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC101US-385. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3314970\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC101US-385 (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":67388259074338,"sku":"DAC101US-385","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513475.webp?v=1790468634"},{"product_id":"citel-dac101us-440","title":"DAC101US-440 Citel Type 1 Surge Protector, 395 V 1PH, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC101US-440 is a Type 1 surge protective device for 395 V 1PH circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (File Number E326289). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eUL1449 5th edition, Type 1 SPD, Imax-100kA, In-20kA, Visual fault indicator and remote contacts, Pluggable\/Replaceable Modules, 10-Year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC101US-440 specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC101US-440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110083\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 5th Ed. TYPE 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL Listed (File Number E326289)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e395V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1PH, 1W+G, Single Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDin Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e0.29 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC101US-440. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3314971\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC101US-440 (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":67388259107106,"sku":"DAC101US-440","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513470.webp?v=1790468634"},{"product_id":"citel-dac102us-120t-nn","title":"DAC102US-120T\/NN Citel Type 1 Surge Protector, 120\/240 V 1PH Split Phase, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC102US-120T\/NN is a Type 1 surge protective device for 120\/240 V 1PH split phase circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (File Number E326289). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eUL1449 5th edition, Type 1 SPD, Imax-100kA, In-20kA, Visual fault indicator and remote contacts, Pluggable\/Replaceable Modules, 10-Year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC102US-120T\/NN specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC102US-120T\/NN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110094\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 TYPE 1 LISTED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL Listed (File Number E326289)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e120\/240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1PH, 2W+G, Split Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e420\/210 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1200\/700 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN RAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1.20 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC102US-120T\/NN. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3177193\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC102US-120T\/NN (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":67388259139874,"sku":"DAC102US-120T\/NN","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513492.webp?v=1790468636"},{"product_id":"citel-dac102us-230s","title":"DAC102US-230S Citel Type 1 Surge Protector, 230 V 1PH, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC102US-230S is a Type 1 surge protective device for 230 V 1PH circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (File Number E326289). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eUL1449 5th edition, Type 1 SPD, Imax-100kA, In-20kA, Visual fault indicator and remote contacts, Pluggable\/Replaceable Modules, 10-Year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC102US-230S specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC102US-230S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110092\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 TYPE 1 LISTED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL Listed (File Number E326289)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1PH, 2W+G, Single Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-N, L-G, N-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e320\/595\/275 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1000\/1800\/900 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN RAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1.20 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC102US-230S. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3177191\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC102US-230S (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":67388259172642,"sku":"DAC102US-230S","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513498.webp?v=1790468636"},{"product_id":"citel-dac102us-230s-g","title":"DAC102US-230S\/G Citel Type 1 Surge Protector, 230 V 1PH, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC102US-230S\/G is a Type 1 surge protective device for 230 V 1PH circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (File Number E326289). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eUL1449 5th edition, Type 1 SPD, Imax-100kA, In-20kA, Visual fault indicator and remote contacts, Pluggable\/Replaceable Modules, 10-Year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC102US-230S\/G specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC102US-230S\/G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110093\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 TYPE 1 LISTED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL Listed (File Number E326289)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1PH, 2W+G, Single Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-N, L-G, N-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e320\/320\/277 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1000\/1500\/1200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN RAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1.20 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC102US-230S\/G. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3177192\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC102US-230S\/G (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":67388266545442,"sku":"DAC102US-230S\/G","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513495.webp?v=1790468773"},{"product_id":"citel-dac103us-120y-nn","title":"DAC103US-120Y\/NN Citel Type 1 Surge Protector, 120\/208 V 3PH, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC103US-120Y\/NN is a Type 1 surge protective device for 120\/208 V 3PH circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (File Number E326289, Categories VZCA, VZCA7). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eUL1449 5th edition, Type 1 SPD, Imax-100kA, In-20kA, Visual fault indicator and remote contacts, Pluggable\/Replaceable Modules, 10-Year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC103US-120Y\/NN specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC103US-120Y\/NN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL Listed (File Number E326289, Categories VZCA, VZCA7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e120\/208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3PH, 3W+G, No Neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e300\/150 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e900\/600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN RAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e0.83 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC103US-120Y\/NN. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3314974\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC103US-120Y\/NN (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":67388266578210,"sku":"DAC103US-120Y\/NN","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513511.webp?v=1790468774"},{"product_id":"citel-dac103us-240t","title":"DAC103US-240T Citel Type 1 Surge Protector, 240\/480 V 1PH Split Phase, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC103US-240T is a Type 1 surge protective device for 240\/480 V 1PH split phase circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (File Number E326289, Categories VZCA, VZCA7). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eType 1 Surge Protective Device with 100kA maximum current, 20kA nominal discharge current, modular DIN rail mounting, visual fault indicator, remote contacts, and 10-year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC103US-240T specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC103US-240T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110106\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL Listed (File Number E326289, Categories VZCA, VZCA7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e240\/480, 120\/240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1PH, 2W+G, Split Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-N, L-G, N-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e770\/385\/705\/320 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e2000\/1200\/1800\/1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN RAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e0.83 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC103US-240T. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3314975\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC103US-240T (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":67388266610978,"sku":"DAC103US-240T","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513509.webp?v=1790468775"},{"product_id":"citel-dac104us-230y","title":"DAC104US-230Y Citel Type 1 Surge Protector, 230\/400 V 3PH Wye, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC104US-230Y is a Type 1 surge protective device for 230\/400 V 3PH wye circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (File Number E326289). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eUL1449 5th edition, Type 1 SPD, Imax-100kA, In-20kA, Visual fault indicator and remote contacts, Pluggable\/Replaceable Modules, 10-Year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC104US-230Y specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC104US-230Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110126\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 TYPE 1 LISTED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL Listed (File Number E326289)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e230\/400, 120\/208 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3PH, 4W+G, Wye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-N, L-G, N-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e640\/320\/595\/275 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1800\/1000\/1800\/900 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN RAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1.32 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC104US-230Y. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3314980\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC104US-230Y (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":67388266643746,"sku":"DAC104US-230Y","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513533.webp?v=1790468776"},{"product_id":"citel-dac104us-240d-g","title":"DAC104US-240D\/G Citel Type 1 Surge Protector, 240 V 3PH Delta, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC104US-240D\/G is a Type 1 surge protective device for 240 V 3PH delta circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (File Number E326289). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eUL1449 5th edition, Type 1 SPD, Imax-100kA, In-20kA, Visual fault indicator and remote contacts, Pluggable\/Replaceable Modules, 10-Year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC104US-240D\/G specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC104US-240D\/G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 TYPE 1 LISTED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL Listed (File Number E326289)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3PH, 3W+G, Delta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e550V \/ 275V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1500V \/ 1500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN RAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1.32 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC104US-240D\/G. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3314985\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC104US-240D\/G (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":67388266676514,"sku":"DAC104US-240D\/G","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513523.webp?v=1790468776"},{"product_id":"citel-dac104us-240y-g","title":"DAC104US-240Y\/G Citel Type 1 Surge Protector, 240\/415 V 3PH Wye, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC104US-240Y\/G is a Type 1 surge protective device for 240\/415 V 3PH wye circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (File Number E326289). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp\u003eUL1449 5th edition, Type 1 SPD, Imax-100kA, In-20kA, Visual fault indicator and remote contacts, Pluggable\/Replaceable Modules, 10-Year warranty.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC104US-240Y\/G specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC104US-240Y\/G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 TYPE 1 LISTED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL Listed (File Number E326289)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e240\/415, 120\/208, 230\/400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3PH, 4W+G, Wye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-N, L-G, N-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e640\/320\/320\/277 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1800\/1000\/1500\/1200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN RAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1.32 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC104US-240Y\/G. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3314983\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC104US-240Y\/G (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":67388266774818,"sku":"DAC104US-240Y\/G","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513527.webp?v=1790468814"}],"url":"https:\/\/aci-automation.com\/collections\/citel.oembed","provider":"Applied Control","version":"1.0","type":"link"}