{"product_id":"block-lr3-48-3-1600-line-reactor","title":"LR3 48-3\/1600 Block Line Reactor, 1600 A, 3% Impedance, 480 V, 1400 HP","description":"\u003cp\u003eThe Block LR3 48-3\/1600 is a 3 phase line reactor rated 1600 A at 480 V with 3% impedance. Block USA rates it for 1400 HP at 480 V and lists about 0.01 mH per phase (rounded). It is UL 508 Listed and cULus marked, open frame (IP00), with copper windings and flat copper terminals. Applied Control is the Block manufacturers' representative. Send the catalog number, or the drive HP, voltage and impedance you need, and we send back a quote.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote?part=LR3%2048-3%2F1600\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eLR3 48-3\/1600 specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:40%;\"\u003eCatalog number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eLR3 48-3\/1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:40%;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eBlock Transformatoren-Elektronik (Block USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:40%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eLR3 line reactor, 3 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:40%;\"\u003eRated current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3 x 1600 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:40%;\"\u003eInductance (Block USA line reactor brochure, rounded)\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3 x 0.01 mH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:40%;\"\u003eImpedance (short circuit voltage)\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3% at 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:40%;\"\u003eRated voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:40%;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e50 to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:40%;\"\u003eHP at 480 V (Block USA line reactor brochure)\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1400 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:40%;\"\u003eInsulation class\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNot listed on the Block product page yet. Ask us and we confirm it with Block.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:40%;\"\u003eProtection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eIP00, open core and coil, mount inside an enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:40%;\"\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-10 to 40 C (14 to 104 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:40%;\"\u003eMax. installation height\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1,000 m (3,281 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:40%;\"\u003eTerminals\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eFlat copper bus connections for line and load, bolt connection for ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:40%;\"\u003eWinding material\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:40%;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e552 x 410 x 272 mm (21.73 x 16.14 x 10.71 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:40%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e179.56 kg (395.86 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:40%;\"\u003eStandards and listings\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL 508 Listed, cULus, EN 61558-2-20, RoHS (EN IEC 63000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the \u003ca href=\"https:\/\/www.block.eu\/en_EN\/productversion\/lr3-48-31600\" target=\"_blank\" rel=\"noopener\"\u003eBlock product page for LR3 48-3\/1600\u003c\/a\u003e. Rated current, inductance and HP from the Block USA line reactor brochure (2026\/27), because the Block product page does not list them yet. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003ch2\u003eCrossing to LR3 48-3\/1600\u003c\/h2\u003e\u003cp\u003eThe Block USA cross reference table stops at 500 HP (630 A), so it lists no Rockwell 1321, MTE, TCI, Acme or Hammond Power Solutions part at 1600 A. For a larger drive, send the competitor part number or the drive nameplate and we check the Block rating with you. The table up to 500 HP is on the \u003ca href=\"\/pages\/line-reactor-cross-reference-to-block\"\u003eline reactor cross reference page\u003c\/a\u003e.\u003c\/p\u003e\u003ch2\u003eNearby sizes\u003c\/h2\u003e\u003cp\u003eNext 3% size: \u003ca href=\"\/products\/block-lr3-48-3-1400-line-reactor\"\u003eLR3 48-3\/1400\u003c\/a\u003e. Same current at 5% impedance: \u003ca href=\"\/products\/block-lr3-48-5-1600-line-reactor\"\u003eLR3 48-5\/1600\u003c\/a\u003e.\u003c\/p\u003e\u003ch2\u003e3% or 5%?\u003c\/h2\u003e\u003cp\u003eA 3% reactor on the drive input cuts line notching and nuisance overvoltage trips and is the usual default. A 5% reactor cuts input current harmonics further and gives more protection when the supply is stiff or has capacitor switching upstream. On the output side, a reactor slows voltage rise at the motor on longer lead runs. Send the drive model and motor lead length and we will size it with you. See \u003ca href=\"\/pages\/line-reactor-vs-load-reactor\"\u003eline reactor vs load reactor\u003c\/a\u003e, the \u003ca href=\"\/collections\/block\"\u003eBlock collection\u003c\/a\u003e, \u003ca href=\"\/collections\/ac-drives\"\u003eTECO AC drives\u003c\/a\u003e and the \u003ca href=\"\/pages\/cross-reference\"\u003ecross reference hub\u003c\/a\u003e.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote?part=LR3%2048-3%2F1600\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 30 Minutes to Review the Application\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eRockwell Automation, MTE, TCI, Acme and Hammond Power Solutions are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Block","offers":[{"title":"Default Title","offer_id":67816922251554,"sku":"LR3 48-3\/1600","price":0.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/aci-automation.com\/products\/block-lr3-48-3-1600-line-reactor","provider":"Applied Control","version":"1.0","type":"link"}