{"product_id":"citel-dac104us-600d","title":"DAC104US-600D Citel Type 1 Surge Protector, 600 V 3PH Delta, 100 kA DIN Rail","description":"\u003cp\u003eThe Citel DAC104US-600D is a Type 1 surge protective device for 600 V 3PH delta circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (File: E326289). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDAC104US-600D specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC104US-600D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eCitel item number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e55110136\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDAC100US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSPD type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL1449 5th edition Type 1 SPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eListing\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eUL Listed (File: E326289)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eNominal voltage\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e600V, 240V, 480V (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e3-phase, 3-wire + ground, Delta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModes of protection\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eL-L, L-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMCOV\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e880V \/ 880V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eVPR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e2500V \/ 2500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eIn, nominal discharge current\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eImax\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eSCCR\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eDIN RAIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eNEMA 2 (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e1.32 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eRemote contact\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003eVisual indicator and remote contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eModules\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003ePluggable\/Replaceable Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;font-weight:700;width:38%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;border:1px solid #ddd;\"\u003e10-Year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003e\u003csmall\u003eSpecifications from the Citel product page for DAC104US-600D. Confirm against the current datasheet before installation.\u003c\/small\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/citel.us\/serverFile\/downloadBinGetSpreadsheet?itemId=3314988\u0026amp;langId=0\" target=\"_blank\" rel=\"noopener\"\u003eCitel datasheet for DAC104US-600D (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eSelecting the right SPD\u003c\/h2\u003e\u003cp\u003eMatch the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the \u003ca href=\"\/pages\/data-centers\"\u003edata center component map\u003c\/a\u003e for where SPDs land in a facility.\u003c\/p\u003e\u003ch2\u003eCross reference\u003c\/h2\u003e\u003cp\u003eHave an Eaton, Siemens, Square D, ABB, Phoenix Contact, Mersen or Littelfuse surge protector part number? Send it with the system voltage and we will cross it to the matching Citel model.\u003c\/p\u003e\u003cp style=\"margin:18px 0;\"\u003e\u003ca href=\"\/pages\/request-a-quote\" style=\"display:inline-block;background:#1F3864;color:#fff!important;padding:11px 20px;text-decoration:none;font-weight:700;border-radius:4px;margin:0 8px 8px 0;\"\u003eRequest a Quote\u003c\/a\u003e\u003ca href=\"https:\/\/calendly.com\/christian-lauderback\/30min\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#fff;color:#1F3864!important;border:2px solid #1F3864;padding:9px 18px;text-decoration:none;font-weight:700;border-radius:4px;\"\u003eBook 15 Minutes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eEaton, Siemens, Square D, ABB, Phoenix Contact, Mersen and Littelfuse are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.\u003c\/small\u003e\u003c\/p\u003e","brand":"Citel","offers":[{"title":"Default Title","offer_id":52626002346274,"sku":"DAC104US-600D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0718\/0812\/3170\/files\/3513517.webp?v=1790364850","url":"https:\/\/aci-automation.com\/products\/citel-dac104us-600d","provider":"Applied Control","version":"1.0","type":"link"}