DAC104US-230Y Citel Type 1 Surge Protector, 230/400 V 3PH Wye, 100 kA DIN Rail

SKU: DAC104US-230Y
Request a Quote Book 15 Minutes with an Application Engineer

Priced within one business day. Factory-direct pricing from an authorized rep. Replacing a competitor part? Send the number and we cross it.

Questions or Require Additional Information?

Call us Today at +1-248-830-4850

The Citel DAC104US-230Y is a Type 1 surge protective device for 230/400 V 3PH wye circuits, DIN rail mounting, with Imax 100 kA and In 20 kA. It is UL listed (File Number E326289). Applied Control is the Citel representative for Michigan and Indiana. Send the part number, or the one-line and the circuit it protects, and the quote comes back the same business day.

UL1449 5th edition, Type 1 SPD, Imax-100kA, In-20kA, Visual fault indicator and remote contacts, Pluggable/Replaceable Modules, 10-Year warranty.

Request a QuoteBook 15 Minutes

DAC104US-230Y specifications

Model DAC104US-230Y
Citel item number 55110126
Series DAC100US
SPD type UL1449 TYPE 1 LISTED
Listing UL Listed (File Number E326289)
Nominal voltage 230/400, 120/208 V
Configuration 3PH, 4W+G, Wye
Modes of protection L-L, L-N, L-G, N-G
MCOV 640/320/595/275 V
VPR 1800/1000/1800/900 V
In, nominal discharge current 20 kA
Imax 100 kA
SCCR 200 kA
Mounting DIN RAIL
Enclosure rating NEMA 2 (IP20)
Weight 1.32 lbs
Remote contact Visual indicator and remote contacts
Modules Pluggable/Replaceable Modules
Operating temperature -40 C to +85 C
Warranty 10-Year

Specifications from the Citel product page for DAC104US-230Y. Confirm against the current datasheet before installation.

Citel datasheet for DAC104US-230Y (PDF)

Selecting the right SPD

Match the SPD type to the location first. A Type 1 device can sit on the line side of the service disconnect; a Type 2 cannot. Then match the system voltage and configuration, because the configuration sets the modes of protection. Check MCOV against the actual line voltage, and use VPR to judge what the connected equipment sees. In is the repeat rating, Imax is the single shot rating; size on In. Send the one-line and we will pick the model with you. See the data center component map for where SPDs land in a facility.

Cross reference