Automotive Plant Panels, Motors and Controls

Pick each part by the area it lives in. Dry body and assembly areas take Type 12 panels; hose-down and paint pretreatment areas take Type 4X. Machining areas with oil mist need closed-loop panel cooling, not filter fans. Below are the parts we carry for each area, with links to the specs.

Request a QuoteBook 30 Minutes to Review the Application

Step 1: Pick by area

Area Panel rating Panel cooling Motors
Body shop, final assembly, warehouse (dry, dusty) Type 12 steel. Hammond 1418 and 1422 wallmounts, 1485 and 1487 wireway Pfannenberg Filterfans if the air is clean; air conditioner if it is not TEFC TECO Westinghouse NEMA Premium; Bison fractional HP gearmotors
Paint pretreatment, wash, wet process Type 4X: 304 stainless (Hammond) or fiberglass (Stahlin) Stainless Pfannenberg air conditioner rated NEMA 4/4X TECO stainless washdown, TEFC IP66
Powertrain machining (oil and coolant mist) Type 12 or Type 13 with gasketed doors Closed loop only: air conditioner, or heat exchanger when the shop stays cooler than the panel target TEFC TECO motors; Tekima VFD cable on drives
Conveyors and material handling Type 12 drive and control panels Size cooling on drive losses (cooling guide) TECO inverter duty motors on VFDs; Block line reactors on the drive

Step 2: Control power and protection

Need What we carry Where to start
480 V to 120 V control power Micron Group A control transformers, 240 x 480 V primary, 120 V secondary, 50 VA to 5 kVA Micron by kVA · VA sizing
600 V plants (Canada) Micron Group E, 550/575/600 V primary, 110/115/120 V secondary, 50 to 750 VA Micron
208 V line to a 230 V motor Micron buck-boost, Groups A, B and C, 50 VA to 7.5 kVA Buck-boost sizing
24 VDC control power Block power supplies Power supplies
Branch fusing and power distribution Marathon Special Products Class J and Class CC fuse holders, power distribution blocks Marathon
Terminal blocks Wieland WTN screw and WTPN push-in terminal blocks WTN · WTPN
Drive input and long motor leads Block line and load reactors Line vs load reactor · Long motor leads
Surge protection Citel surge protective devices Citel
Andon and machine status Pfannenberg stack lights, beacons and sounders Stack lights · Signaling
Cable tray and cable entry Basor wire mesh tray; Aeros USA AGRO cable glands Basor · Aeros USA

Replacing a part you already have?

Send the old part number. We cross Hoffman, Rittal and Saginaw enclosures, Square D, Acme, Siemens, GE, HPS, Jefferson and Sola control transformers, Bussmann fuses, MTE reactors and more. Start at the cross reference index.

Common questions

Type 12 or Type 4X for a body shop panel?

Type 12 is the usual pick for dry, dusty areas. Use Type 4X where the panel gets hosed down or sees corrosive washes, such as paint pretreatment.

Can I use filter fans on a machining line panel?

Not where there is oil or coolant mist. The filter loads up and the mist gets inside. Use a closed-loop air conditioner, or a heat exchanger when the shop air stays cooler than the panel target.

What control transformer for a 480 V conveyor panel?

A Micron Group A unit: 240 x 480 V primary, 120 V secondary. Size it on the inrush VA of the coils that pull in at once, not just the sealed VA.

What do I use in a 600 V plant?

Micron Group E control transformers, 550/575/600 V primary, 110/115/120 V secondary, 50 to 750 VA.

Can you cross the parts on our current drawings?

Yes. Send the bill of materials or the old part numbers. We send back the equivalent parts and lead times.

Get the line quoted

Send the drawings, the bill of materials or a list of part numbers. We quote the panel parts, motors and controls together.

Request a QuoteBook 30 Minutes to Review the Application

Related: Enclosure cooling guide · Air conditioner vs heat exchanger · NEMA ratings · TECO motors · Enclosures · All cross references