Water and Wastewater Pump Motors, Drives and Panels

Deep well turbine pumps and vertical lift pumps take a vertical hollow shaft (VHS) motor with a non-reverse ratchet. Run it on a pump drive with built-in PID and pump cascade, and house the controls in a Type 4X panel with sealed cooling. Jobs paid with federal infrastructure money may also need Build America, Buy America (BABAA) listed parts. The tables below give the ratings and part numbers for each piece.

Request a QuoteBook 30 Minutes to Review the ApplicationCall 248-830-4850

Step 1: Pick the pump motor

Motor Enclosure HP and speed Voltage
TECO Westinghouse MAX-VHP / MAX-VH vertical hollow shaft, WPI, low voltage [VHP] Weather Protected Type I 7.5 to 800 HP, 1800 RPM 230/460 V (150 HP and up 460 V only)
TECO Westinghouse MAX-VHP vertical hollow shaft, TEFC, low voltage [VHTP] TEFC, IP55. CSA Class I, Div. 2, Groups B, C, D, T3 15 to 800 HP, 1800 and 1200 RPM 230/460 V (150 HP and up 460 V only)
TECO Westinghouse vertical hollow shaft, WPI, medium voltage [VHKP] Weather Protected Type I 200 to 1,000 HP, 1800 and 1200 RPM 2300/4000 V
TECO Westinghouse vertical hollow shaft, TEFC, medium voltage [VHKTP] TEFC 200 to 700 HP, 1800 and 1200 RPM 2300/4000 V
TECO Westinghouse MAX-PE horizontal (end suction pumps, blowers, aeration) TEFC, IP54 1 to 200 HP, 3600, 1800 and 1200 RPM 230/460 V

Step 2: Pick the pump drive

The TECO Westinghouse F510 is TECO's fan and pump drive. TECO lists wastewater, irrigation and industrial pumping as target uses.

F510 feature What TECO lists
Range 1 to 800 HP at 460 V and 1 to 150 HP at 230 V, variable torque
Pump cascade Built in for up to 4 pumps (1 master, 3 followers). Up to 8 pumps with the JN5-IO-8D0 card
Process control Two PID loops, switch by input or real time clock. Sleep mode
Communications Modbus RTU, BACnet MS/TP and Metasys N2 on board (RS485 or RJ45)
Overload 120% for 1 minute
Built for damp rooms Conformal coating on all printed circuit boards
Motor protection PTC input for direct motor thermal protection

Common sizes on this site: F510-4025-C3-UE (25 HP), F510-4050-C3-UE (50 HP), F510-4100-C3-UE (100 HP) and F510-4215-C3-UE (200 HP).

On a VHS motor with a non-reverse ratchet, TECO rates the speed range at 10:1 variable torque. Without the ratchet and with braking in the drive, it is 20:1. Long cable runs out to a well or lift station need a check on carrier frequency and motor peak voltage. See long motor leads on a VFD and line reactor vs load reactor. A Rex 3PR-0060C3H is the 60 A, 3%, 480 V reactor for a 40 HP drive.

Step 3: Outdoor panels, cooling and alarms

Part What it is Rating
Stahlin J1210W Fiberglass enclosure, 11.79 x 9.8 x 4.94 in, opaque cover NEMA 4X
Hammond 1418N4S16B6 Wallmount enclosure, 16 x 12 x 6 in, 316 stainless Type 4X
Pfannenberg DTS 3081, 13382341159 Air conditioner, 230 V, 750 W (2,000 to 3,000 BTU/hr), 316 stainless NEMA 4/4X, BABAA listed
Pfannenberg DTS 3185, 13383639159 Air conditioner, 230 V, 1,900 W (5,000 to 7,000 BTU/hr), 316 stainless NEMA 4/4X, BABAA listed
Pfannenberg PATROL PA L 5, 23353158055 RGB LED beacon with sounder, 107 dB, 115 VAC High level and pump fail alarm

Size the cooling with the heat load calculator and the enclosure cooling guide. Fiberglass or stainless? Both are Type 4X. See NEMA 4 vs 4X vs 12. All Stahlin boxes are in the Stahlin collection.

BABAA listed Pfannenberg units on this site

Pfannenberg lists these units as BABAA compliant: over 55% U.S. sourced content, assembled in Lancaster, NY. Ask for the Pfannenberg BABAA certificate with the quote.

Part number Model Voltage Capacity Material
13382344159 DTS 3081 115 V 750 W 316 stainless
13382341159 DTS 3081 230 V 750 W 316 stainless
13382336159 DTS 3081 460 V 750 W 316 stainless
13382344300 DTS 3081 115 V 750 W 304 stainless
13385444159 DTS 3181 115 V 1,300 W 316 stainless
13385441159 DTS 3181 230 V 1,300 W 316 stainless
13385436159 DTS 3181 460 V 1,300 W 316 stainless
13383436158 DTS 3181 SL 460 V 1,500 W 304 stainless
13383644159 DTS 3185 115 V 1,900 W 316 stainless
13383639159 DTS 3185 230 V 1,900 W 316 stainless
13383636159 DTS 3185 460 V 1,900 W 316 stainless

Common questions

What does the non-reverse ratchet do?

It stops the shaft from spinning backward when the pump stops and the water column drains back down the column pipe. TECO ships a ball type NRR as standard on its low voltage VHS motors.

Can a vertical hollow shaft motor run on a VFD?

Yes. TECO rates its VHS motors inverter duty per NEMA MG 1 Part 31 at a 1.0 service factor. With the ratchet in place the range is 10:1 variable torque.

WPI or TEFC?

TECO builds both. The WPI line starts at 7.5 HP. The TEFC line starts at 15 HP, is IP55 and carries CSA Class I, Div. 2 for Groups B, C and D. Pick TEFC when the motor sits in a classified or dirty area.

How many pumps can one F510 run?

Up to 4 with the built-in cascade: one master and up to 3 followers. Add the JN5-IO-8D0 card for up to 8.

Which cooling units meet BABAA?

Pfannenberg lists select DTS 3081, 3181, 3185, 3281 and 3285 cooling units plus select PKS and PWS heat exchangers. The table above shows the ones on this site.

Get the station quoted

Send the pump HP, speed, thrust and voltage, the number of pumps, the cable length to the motor and the panel size. We send back the TECO motor and drive, reactors, enclosure and cooling as one quote with lead times.

Request a QuoteBook 30 Minutes to Review the ApplicationCall 248-830-4850

Related: TECO motors · TECO AC drives · Rex Power Magnetics · Stahlin enclosures · Pfannenberg · Enclosure cooling guide · Transformer quote · Data center components · All cross references