The Block LR3 48-3/300 is a 3 phase line reactor rated 300 A at 480 V with 3% impedance (0.074 mH per phase). Block USA rates it for 250 HP at 480 V. It is UL 508 Listed and cULus marked, open frame (IP00), with copper windings and class F insulation. Applied Control is the Block manufacturers' representative. Send the catalog number, or the drive HP, voltage and impedance you need, and we send back a quote.
Request a QuoteBook 30 Minutes to Review the Application
LR3 48-3/300 specifications
| Catalog number | LR3 48-3/300 |
| Manufacturer | Block Transformatoren-Elektronik (Block USA) |
| Series | LR3 line reactor, 3 phase |
| Rated current | 3 x 300 A AC |
| Linear current | 3 x 450 A AC |
| Inductance | 3 x 0.074 mH |
| Impedance (short circuit voltage) | 3% at 480 V |
| Rated voltage | 480 V (voltage range 0 to 690 V) |
| Frequency | 50 to 60 Hz |
| HP at 480 V (Block USA line reactor brochure) | 250 HP |
| Motor or converter power (Block product page) | 200 kW (268.2 HP) |
| Insulation class | F (155 C), UL class 155 |
| Duty cycle | 100% |
| Protection | IP00, open core and coil, mount inside an enclosure |
| Ambient temperature | -10 to 40 C (14 to 104 F) |
| Max. installation height | 1,000 m (3,281 ft) |
| Terminals | Flat copper bus connections for line and load, bolt connection for ground |
| Winding material | Copper |
| Dimensions (W x H x D) | 352 x 328 x 144 mm (13.86 x 12.91 x 5.67 in) |
| Weight | 33.66 kg (74.21 lb) |
| Standards and listings | UL 508 Listed, cULus, EN 61558-2-20, RoHS (EN IEC 63000) |
Specifications from the Block product page for LR3 48-3/300. HP rating from the Block USA line reactor brochure where listed. Confirm against the current datasheet before installation.
Crossing to LR3 48-3/300
The Block USA cross reference table steps from one standard rating to the next and does not list a Rockwell 1321, MTE, TCI, Acme or Hammond Power Solutions part at exactly 300 A. If your drive input current lands between the table sizes, this rating can be the closer fit. Send the competitor part number or the drive nameplate and we check it with you. The full table is on the line reactor cross reference page.
Nearby sizes
Next 3% sizes: LR3 48-3/250 and LR3 48-3/400. Same current at 5% impedance: LR3 48-5/300.
3% or 5%?
A 3% reactor on the drive input cuts line notching and nuisance overvoltage trips and is the usual default. A 5% reactor cuts input current harmonics further and gives more protection when the supply is stiff or has capacitor switching upstream. On the output side, a reactor slows voltage rise at the motor on longer lead runs. Send the drive model and motor lead length and we will size it with you. See line reactor vs load reactor, the Block collection, TECO AC drives and the cross reference hub.
Request a QuoteBook 30 Minutes to Review the Application
Rockwell Automation, MTE, TCI, Acme and Hammond Power Solutions are trademarks of their respective owners. Applied Control Inc. is not affiliated with these companies. Competitor names appear only to identify products for comparison.