Acme FS Finger-Guard Control Transformer Cross Reference to Micron

Acme Finger-Guard FS series control transformers cross to Micron GlobalTRAN by VA and group. FS-2-100 (FS2100, 100 VA, 230 x 460 V to 115 V) crosses to Micron B100-2003-GA. Current Acme numbers drop the dashes, so FS-2-100 and FS2100 are the same part. Find the group digit after FS, then read across at the same VA.

Both lines are finger-safe and CE marked. For Acme TA-2, TA-69, TA-83 and ET numbers, use the Acme cross.

Request a QuoteBook 30 Minutes to Review the Application

Jump to your voltage

FS-2: 230x460 to 115 V · FS-1: 120x240 to 24 V · FS-3: universal

Acme FS-2 (Group B): 230 x 460 V primary, 115 V secondary (triple rated)

VA Acme Micron
50 VA FS-2-50, FS250 B050-2001-GA
75 VA FS-2-75, FS275 B075-2002-GA
100 VA FS-2-100, FS2100 B100-2003-GA
150 VA FS-2-150, FS2150 B150-2004-GAF
250 VA FS-2-250, FS2250 B250-2006-GAF
300 VA FS-2-300, FS2300 B300-2007-GAF
350 VA FS-2-350, FS2350 B350-2008-GAF
500 VA FS-2-500, FS2500 B500-2009-GAF
750 VA FS-2-750, FS2750 B750-2010-GAF
1 kVA FS-2-1000, FS21000 B1K0-2008-GAH
1.5 kVA FS-2-1500, FS21500 B1K5-2009-GAH
2 kVA FS-2-2000, FS22000 B2K0-2010-GAH
3 kVA FS-2-3000, FS23000 B3K0-2011-GAH

Micron GlobalTRAN Group A: 230 x 460 V primary, 115 V secondary, triple rated. CE marked per the CB Scheme and IEC 61558. Micron also builds 200 VA (B200-2005-GAF) and 5 kVA (B5K0-2012-GAH) in this group.

Acme FS-1 (Group A): 120 x 240 V primary, 24 V secondary

VA Acme Micron
50 VA FS-1-50, FS150 B050-2021-GA
75 VA FS-1-75, FS175 B075-2022-GA
100 VA FS-1-100, FS1100 B100-2023-GA
150 VA FS-1-150, FS1150 B150-2024-GAF
250 VA FS-1-250, FS1250 B250-2026-GAF
350 VA FS-1-350, FS1350 B350-2028-GAF
500 VA FS-1-500, FS1500 B500-2029-GAF
750 VA FS-1-750, FS1750 B750-2030-GAF
1 kVA FS-1-1000, FS11000 B1K0-2048-GAF

Micron GlobalTRAN Group C: 120 x 240 V primary, 24 V secondary. Micron also builds 200 VA (B200-2025-GAF) and 300 VA (B300-2027-GAF) in this group.

Acme FS-3 (Group C): universal multi-tap primary 208 to 600 V, 85 to 130 V secondary

VA Acme Micron
50 VA FS-3-50, FS350 Ask us
150 VA FS-3-150, FS3150 Ask us
250 VA FS-3-250, FS3250 B250-2283-GAF
350 VA FS-3-350, FS3350 B350-2285-GAF
500 VA FS-3-500, FS3500 B500-2286-GAF
750 VA FS-3-750, FS3750 B750-2287-GAF
1 kVA FS-3-1000, FS31000 B1K0-2288-GAH
1.5 kVA FS-3-1500, FS31500 B1K5-2289-GAH
2 kVA FS-3-2000, FS32000 B2K0-2290-GAH
3 kVA FS-3-3000, FS33000 B3K0-2291-GAH

Micron GlobalTRAN Group H universal: primary taps 240/416/480/600, 230/400/460/575, 220/380/440/550 and 208/500 V; secondary 99/120/130, 95/115/125, 91/110/120 and 85/100/110 V. The sheet lists no Micron match at 50 and 150 VA; we check the next size up.

How to read an Acme FS number

FS is the Acme Finger/Guard control transformer. The digit after FS is the voltage group: 1 is 120 x 240 V to 24 V, 2 is 230 x 460 V to 115 V, 3 is the universal multi-tap unit. The last digits are the VA. FS-2-250 (FS2250) is 250 VA, 230 x 460 V to 115 V, and crosses to Micron B250-2006-GAF.

Common questions

What Micron transformer replaces Acme FS2100?

Micron GlobalTRAN B100-2003-GA, 100 VA, 230 x 460 V primary, 115 V secondary. FS2100 is the current number for FS-2-100.

What replaces Acme FS-1-100 (24 V)?

Micron GlobalTRAN B100-2023-GA, 100 VA, 120 x 240 V primary, 24 V secondary.

What replaces Acme FS-2-1000?

Micron GlobalTRAN B1K0-2008-GAH, 1 kVA, 230 x 460 V primary, 115 V secondary.

Are the Micron GlobalTRAN units CE marked?

Yes. The sheet lists them as CE marked in accordance with the CB Scheme and IEC 61558.

Get it crossed and quoted

Send the Acme number and the quantity. We send back the Micron part and lead time.

Request a QuoteBook 30 Minutes to Review the Application

Related: Acme TA-2, TA-69, TA-83 and ET cross · Square D 9070T cross · HPS PT cross · Micron control transformers by kVA · Control transformer VA sizing · All cross references