Square D 9070T Control Transformer Cross Reference to Micron

Square D Class 9070 Type T control transformers cross to Micron by VA and voltage code. The most common one, 9070T100D1 (100 VA, 230 x 460 V to 115 V), crosses to Micron B100BTZ13JK. Find the D code at the end of your Square D number, then read across at the same VA.

Request a QuoteBook 30 Minutes to Review the Application

Jump to your voltage code

D1 · D2 · D5 · D3, D20, D27 · D4, D51 · D6, D17, D33 · D7, D23 · D12, D31 · D32

Square D D1: 230 x 460 V primary, 115 V secondary

Micron Group A: 220x440/230x460/240x480 V primary, 110/115/120 V secondary.

VA Square D Micron
50 VA 9070T50D1 B050BTZ13JK
75 VA 9070T75D1 B075BTZ13JK
100 VA 9070T100D1 B100BTZ13JK
150 VA 9070T150D1 B150BTZ13JK
200 VA 9070T200D1 B200BTZ13JK
250 VA 9070T250D1 B250BTZ13JK
300 VA 9070T300D1 B300BTZ13JK
350 VA 9070T350D1 B350BTZ13JK
500 VA 9070T500D1 B500BTZ13JK
750 VA 9070T750D1 B750BTZ13JK
1 kVA 9070T1000D1 EF1K0BTZ13
1.5 kVA 9070T1500D1 EF1K5BTZ13
2 kVA 9070T2000D1 EF2K0BTZ13
3 kVA 9070T3000D1 EF3K0BTZ13
5 kVA 9070T5000D1 EF5K0BTZ13

Micron lists VF1K0BTZ13JK (ValuTRAN) as a second 1 kVA option. We also list Micron Group A ImperviTRAN at 1 to 5 kVA: 1 kVA, 1.5 kVA, 2 kVA, 3 kVA, 5 kVA.

Square D D2: 230 x 460 V primary, 24 V secondary

Micron Group B: 240 x 480 V primary, 24 V secondary.

VA Square D Micron
50 VA 9070T50D2 B050PU7JK
75 VA 9070T75D2 B075PU7JK
100 VA 9070T100D2 B100PU7JK
150 VA 9070T150D2 B150PU7JK
200 VA 9070T200D2 B200PU7JK
250 VA 9070T250D2 B250PU7JK
300 VA 9070T300D2 B300PU7JK
350 VA 9070T350D2 B350PU7JK
500 VA 9070T500D2 B500PU7JK
750 VA 9070T750D2 B750PU7JK

Square D D5: 550/575/600 V primary, 110/115/120 V secondary

Micron Group E: 550/575/600 V primary, 110/115/120 V secondary.

VA Square D Micron
50 VA 9070T50D5 B050WZ13XK
75 VA 9070T75D5 B075WZ13XK
100 VA 9070T100D5 B100WZ13XK
150 VA 9070T150D5 B150WZ13XK
200 VA 9070T200D5 B200WZ13XK
250 VA 9070T250D5 B250WZ13XK
300 VA 9070T300D5 B300WZ13XK
350 VA 9070T350D5 B350WZ13XK
500 VA 9070T500D5 B500WZ13XK
750 VA 9070T750D5 B750WZ13XK
1 kVA 9070T1000D5 EF1K0BTWZ37
1.5 kVA 9070T1500D5 EF1K5BTWZ37
2 kVA 9070T2000D5 EF2K0BTWZ37
3 kVA 9070T3000D5 EF3K0BTWZ37
5 kVA 9070T5000D5 EF5K0BTWZ37

Above 750 VA Micron crosses to EconoTRAN with a 230/460/575 V primary and 95/115 V secondary.

Square D D3, D20, D27: D3: 208 V to 120 V. D20: 208/230/460 V to 115 V. D27: 208/240/480 V to 120 V

Micron Group L: 208/230/460 V primary, 115 V secondary.

VA Square D Micron
50 VA 9070T50D3, 9070T50D20, 9070T50D27 B050MBT13XK
75 VA 9070T75D3, 9070T75D20, 9070T75D27 B075MBT13XK
100 VA 9070T100D3, 9070T100D20, 9070T100D27 B100MBT13XK
150 VA 9070T150D3, 9070T150D20, 9070T150D27 B150MBT13XK
200 VA 9070T200D3, 9070T200D20, 9070T200D27 B200MBT13XK
250 VA 9070T250D3, 9070T250D20, 9070T250D27 B250MBT13XK
300 VA 9070T300D3, 9070T300D20, 9070T300D27 B300MBT13XK
350 VA 9070T350D3, 9070T350D20, 9070T350D27 B350MBT13XK
500 VA 9070T500D3, 9070T500D20, 9070T500D27 B500MBT13XK
750 VA 9070T750D3, 9070T750D20, 9070T750D27 B750MBT13XK
1 kVA 9070T1000D3, 9070T1000D20, 9070T1000D27 EF1K0MBT13
1.5 kVA 9070T1500D3, 9070T1500D20, 9070T1500D27 EF1K5MBT13
2 kVA 9070T2000D3, 9070T2000D20, 9070T2000D27 EF2K0MBT13
3 kVA 9070T3000D3, 9070T3000D20, 9070T3000D27 EF3K0MBT13
5 kVA 9070T5000D3, 9070T5000D20, 9070T5000D27 EF5K0MBT13

D3 and D27 have a 120 V secondary. The Micron unit is 115 V. Check that your loads are fine at 115 V.

Square D D4, D51: D4: 277 V to 120 V. D51: 208/277 V to 120 V

Micron Group F: 208/277 V primary, 120 V secondary.

VA Square D Micron
50 VA 9070T50D4, 9070T50D51 B050MQ15XK
75 VA 9070T75D4, 9070T75D51 B075MQ15XK
100 VA 9070T100D4, 9070T100D51 B100MQ15XK
150 VA 9070T150D4, 9070T150D51 B150MQ15XK
200 VA 9070T200D4, 9070T200D51 B200MQ15XK
250 VA 9070T250D4, 9070T250D51 B250MQ15XK
300 VA 9070T300D4, 9070T300D51 B300MQ15XK
350 VA 9070T350D4, 9070T350D51 B350MQ15XK
500 VA 9070T500D4, 9070T500D51 B500MQ15XK
750 VA 9070T750D4, 9070T750D51 B750MQ15XK

Micron says consult the factory above 750 VA.

Square D D6, D17, D33: D6: 380 V to 110 V. D17: 415 V to 110 V. D33: 380/400/415 V to 115 x 230 V

Micron Group D: 380/400/415 V primary, 110 x 220 V secondary.

VA Square D Micron
50 VA 9070T50D6, 9070T50D17, 9070T50D33 B050RFD34XJ
75 VA 9070T75D6, 9070T75D17, 9070T75D33 B075RFD34XJ
100 VA 9070T100D6, 9070T100D17, 9070T100D33 B100RFD34XJ
150 VA 9070T150D6, 9070T150D17, 9070T150D33 B150RFD34XJ
200 VA 9070T200D6, 9070T200D17, 9070T200D33 B200RFD34XJ
250 VA 9070T250D6, 9070T250D17, 9070T250D33 B250RFD34XJ
300 VA 9070T300D6, 9070T300D17, 9070T300D33 B300RFD34XJ
350 VA 9070T350D6, 9070T350D17, 9070T350D33 B350RFD34XJ
500 VA 9070T500D6, 9070T500D17, 9070T500D33 B500RFD34XJ
750 VA 9070T750D6, 9070T750D17, 9070T750D33 B750RFD34XJ

D33 has a 115 x 230 V secondary. The Micron unit is 110 x 220 V. Micron says consult the factory over 750 VA.

Square D D7, D23: D7: 120 V to 24 V. D23: 120/240 V to 24 V

Micron Group C: 120 x 240 V primary, 24 V secondary.

VA Square D Micron
50 VA 9070T50D7, 9070T50D23 B050LP7JK
75 VA 9070T75D7, 9070T75D23 B075LP7JK
100 VA 9070T100D7, 9070T100D23 B100LP7JK
150 VA 9070T150D7, 9070T150D23 B150LP7JK
200 VA 9070T200D7, 9070T200D23 B200LP7JK
250 VA 9070T250D7, 9070T250D23 B250LP7JK
300 VA 9070T300D7, 9070T300D23 B300LP7JK
350 VA 9070T350D7, 9070T350D23 B350LP7JK
500 VA 9070T500D7, 9070T500D23 B500LP7JK
750 VA 9070T750D7, 9070T750D23 B750LP7JK

Square D D12, D31: D12: 480 V to 240 V. D31: 230 x 460 V to 115 x 230 V

Micron Group K: 240 x 480 V primary, 120 x 240 V secondary.

VA Square D Micron
50 VA 9070T50D12, 9070T50D31 B050PU1519JJ
75 VA 9070T75D12, 9070T75D31 B075PU1519JJ
100 VA 9070T100D12, 9070T100D31 B100PU1519JJ
150 VA 9070T150D12, 9070T150D31 B150PU1519JJ
200 VA 9070T200D12, 9070T200D31 B200PU1519JJ
250 VA 9070T250D12, 9070T250D31 B250PU1519JJ
300 VA 9070T300D12, 9070T300D31 B300PU1519JJ
350 VA 9070T350D12, 9070T350D31 B350PU1519JJ
500 VA 9070T500D12, 9070T500D31 B500PU1519JJ
750 VA 9070T750D12, 9070T750D31 B750PU1519JJ
1 kVA 9070T1000D12, 9070T1000D31 EF1K0BTZ1318
1.5 kVA 9070T1500D12, 9070T1500D31 EF1K5BTZ1318
2 kVA 9070T2000D12, 9070T2000D31 EF2K0BTZ1318
3 kVA 9070T3000D12, 9070T3000D31 EF3K0BTZ1318
5 kVA 9070T5000D12, 9070T5000D31 EF5K0BTZ1318

Above 750 VA Micron crosses to EconoTRAN, 230 x 460 V primary, 115 x 230 V secondary.

Square D D32: 230/460/575 V primary, 115 V secondary

Micron Group H: 230/460/575 V primary, 95/115 V secondary.

VA Square D Micron
50 VA 9070T50D32 B050BTW37XX
75 VA 9070T75D32 B075BTW37XX
100 VA 9070T100D32 B100BTW37XX
150 VA 9070T150D32 B150BTW37XX
200 VA 9070T200D32 B200BTW37XX
250 VA 9070T250D32 B250BTW37XX
300 VA 9070T300D32 B300BTW37XX
350 VA 9070T350D32 B350BTW37XX
500 VA 9070T500D32 B500BTW37XX
750 VA 9070T750D32 B750BTW37XX
1 kVA 9070T1000D32 E1K0BTWZ37
1.5 kVA 9070T1500D32 E1K5BTWZ37
2 kVA 9070T2000D32 E2K0BTWZ37
3 kVA 9070T3000D32 E3K0BTWZ37

How to read a Square D 9070T number

9070T is the Class 9070 Type T control transformer. The number after T is the VA. The D code is the voltage. Type TF adds primary and secondary fusing, and an SF suffix adds secondary fusing. 9070T250D1 is 250 VA, 230 x 460 V to 115 V. The Micron cross is B250BTZ13JK at the same VA. Tell us if you need fusing and we match it.

Common questions

What Micron transformer replaces Square D 9070T100D1?

Micron B100BTZ13JK, a 100 VA Group A ImperviTRAN unit. Primary 220x440, 230x460 or 240x480 V. Secondary 110, 115 or 120 V.

What replaces Square D 9070T50D1?

Micron B050BTZ13JK, 50 VA, Group A, 220x440/230x460/240x480 V primary, 110/115/120 V secondary.

What replaces a Square D D5 (600 V) control transformer?

Micron Group E, the WZ13XK series, for 50 to 750 VA: 550/575/600 V primary, 110/115/120 V secondary. 9070T100D5 crosses to B100WZ13XK.

Does Micron cross Square D Type TF fused transformers?

Yes. The cross sheet notes the Micron fuse block options. Send the 9070TF number and we match the primary and secondary fusing.

Get it crossed and quoted

Send the Square D number and the quantity. We send back the Micron part and lead time.

Request a QuoteBook 30 Minutes to Review the Application

More control transformer crosses: Acme TA-2 · Cutler-Hammer MTE · Siemens MT · GE 9T58 · HPS PT · Jefferson 636 · Sola/Hevi-Duty

Related: Micron control transformers by kVA · Control transformer VA sizing · Buck-boost sizing and cross · Micron · All cross references