Micron JH150A1KC1A14 is a 150 VA Group B buck-boost transformer: 240 x 480 V primary, 24/48 V secondary, single phase, 600 V class. It is the current number for the old Micron J150A1KC1A01. It crosses to Acme T181063 and Square D 150SV82A.
Request a Quote for JH150A1KC1A14Book 30 Minutes to Review the Application
JH150A1KC1A14 specifications
| Part number | JH150A1KC1A14 |
| Replaces Micron number | J150A1KC1A01 (discontinued) |
| Manufacturer | Micron Industries |
| Type | Buck-boost transformer, single phase |
| Voltage group | Group B |
| Primary | 240 x 480 V |
| Secondary | 24/48 V |
| Rating | 150 VA |
| Insulation class | 600 V class |
| Load amps, boost or buck at 48 V | 3.1 A max (VA / 48 V) |
| Load amps, boost or buck at 24 V | 6.2 A max (VA / 24 V) |
| Weight | 10 lb |
| Warranty | 1 year (Micron) |
Source: FactoryMation Micron buck-boost Group B listing (current JH number, weight, group voltages) and Micron buck-boost product page. Load amps are the standard rule: transformer VA divided by the secondary volts in the connection. We confirm the Micron number and the wiring on every quote.
Cross reference
| Brand | Part number |
|---|---|
| Micron (old) | J150A1KC1A01 |
| Acme | T181063 |
| Eaton Cutler-Hammer | S20N08A83N |
| Hevi-Duty | HS22B150 |
| FPC | K2XGF24-0.15 |
| GE | 9T51B0205 |
| HPS (Hammond Power Solutions) | QC15DTCB |
| Jefferson | 416-1411-000 |
| Square D | 150SV82A |
Source: Micron transformer cross reference MINT16A (January 2016), buck-boost section. Check ratings before you swap. Brand names identify the part being replaced; Applied Control is not affiliated with them.
How to use it
In buck or boost, the transformer carries only the added or removed volts. Size it on load amps x secondary volts. Wired as an isolation transformer it gives 24 or 48 VAC. Micron says buck-boost units are mainly for motor loads. Do not use one for a motor control circuit, to fix a swinging line, or to get a neutral on a delta system. On a 208Y/120 grounded system, a boost to 240 V leaves 139 V to ground. For three phase, Micron banks two units (open delta) or three units.
Common questions
What replaces Micron J150A1KC1A01?
JH150A1KC1A14. Same Group B, 240 x 480 V primary, 24/48 V secondary, 150 VA.
What Micron part replaces Acme T181063?
JH150A1KC1A14, 150 VA, Group B.
How much load can a 150 VA buck-boost carry?
About 3.1 A with the 48 V connection, or 6.2 A with the 24 V connection. Send the line volts, load volts and load amps and we check it.