Jefferson Electric 636 series control transformers cross to Micron by VA and voltage. The most common one, 636-1131-200 (100 VA, 230 x 460 V to 115 V), crosses to Micron B100BTZ13JK. The -200 suffix means primary fusing provision and -300 means primary and secondary fusing; both cross to the same Micron part. Tell us which fusing you need.

Request a QuoteBook 30 Minutes to Review the Application

Jump to your voltage

230x460 to 115 V · 240x480 to 120 V, high inrush · 24 V secondary · 208/277 to 120 V · 400 series (CE)

Jefferson 200/300 series: 230 x 460 V primary, 115 V secondary (standard inrush)

VA Jefferson Micron
50 VA 636-1111-200, 636-1111-300 B050BTZ13JK
75 VA 636-1121-200, 636-1121-300 B075BTZ13JK
100 VA 636-1131-200, 636-1131-300 B100BTZ13JK
150 VA 636-1141-200, 636-1141-300 B150BTZ13JK
200 VA 636-1151-200, 636-1151-300 B200BTZ13JK
250 VA 636-1161-200, 636-1161-300 B250BTZ13JK
300 VA 636-1171-200, 636-1171-300 B300BTZ13JK
350 VA 636-1181-200, 636-1181-300 B350BTZ13JK
500 VA 636-1191-200, 636-1191-300 B500BTZ13JK
750 VA 636-1201-200, 636-1201-300 B750BTZ13JK
1 kVA 636-1211-200, 636-1211-300 EF1K0BTZ13
1.5 kVA 636-1221-200, 636-1221-300 EF1K5BTZ13
2 kVA 636-1231-200, 636-1231-300 EF2K0BTZ13
3 kVA 636-1241-200, 636-1241-300 EF3K0BTZ13
5 kVA 636-1261-200, 636-1261-300 EF5K0BTZ13

Micron Group A: 220x440, 230x460 or 240x480 V primary, 110, 115 or 120 V secondary. 1 kVA and up are EconoTRAN, 180°C.

Jefferson 200/300 series: 240 x 480 V primary, 120 V secondary (high inrush)

VA Jefferson Micron
25 VA 636-2401-200, 636-2401-300 B025BTZ13JK
50 VA 636-2411-200, 636-2411-300 B050BTZ13JK
75 VA 636-2421-200, 636-2421-300 B075BTZ13JK
100 VA 636-2431-200, 636-2431-300 B100BTZ13JK
150 VA 636-2441-200, 636-2441-300 B150BTZ13JK
200 VA 636-2451-200, 636-2451-300 B200BTZ13JK
250 VA 636-2461-200, 636-2461-300 B250BTZ13JK
300 VA 636-2471-200, 636-2471-300 B300BTZ13JK
350 VA 636-2481-200, 636-2481-300 B350BTZ13JK
500 VA 636-2491-200, 636-2491-300 B500BTZ13JK
750 VA 636-2501-200, 636-2501-300 B750BTZ13JK
1 kVA 636-2511-200, 636-2511-300 EF1K0BTZ13
1.5 kVA 636-2521-200, 636-2521-300 EF1K5BTZ13
2 kVA 636-2531-200, 636-2531-300 EF2K0BTZ13
3 kVA 636-2541-200, 636-2541-300 EF3K0BTZ13
5 kVA 636-2561-200, 636-2561-300 EF5K0BTZ13

The sheet crosses the high inrush units to the same Micron Group A parts. If your load has a high inrush, send the inrush VA and we check the size.

Jefferson 200/300 series: 240x480, 230x460, 220x440 V primary, 24/23/22 V secondary

VA Jefferson Micron
50 VA 636-1112-200, 636-1112-300 B050MBT713XK
75 VA 636-1122-200, 636-1122-300 B075MBT713XK
100 VA 636-1132-200, 636-1132-300 B100MBT713XK
150 VA 636-1142-200, 636-1142-300 B150MBT713XK
250 VA 636-1162-200, 636-1162-300 B250MBT713XK

Micron MBT713XK: 208/230/460 V primary, 24 and 115 V secondary.

Jefferson 200/300 series: 208/277 V primary, 120 V secondary

VA Jefferson Micron
50 VA 636-1116-200, 636-1116-300 B050MQ15XK
75 VA 636-1126-200, 636-1126-300 B075MQ15XK
100 VA 636-1136-200, 636-1136-300 B100MQ15XK
150 VA 636-1146-200, 636-1146-300 B150MQ15XK
200 VA 636-1156-200, 636-1156-300 B200MQ15XK
250 VA 636-1166-200, 636-1166-300 B250MQ15XK
500 VA 636-1196-200, 636-1196-300 B500MQ15XK
750 VA 636-1206-200, 636-1206-300 B750MQ15XK
1 kVA 636-1216-200, 636-1216-300 Ask us
1.5 kVA 636-1226-200, 636-1226-300 Ask us
2 kVA 636-1236-200, 636-1236-300 Ask us
3 kVA 636-1246-200, 636-1246-300 Ask us
5 kVA 636-1266-200, 636-1266-300 Ask us

Micron Group F: 208/277 V primary, 120 V secondary. Above 750 VA, ask us about the 277 V primary.

Jefferson 400 series (CE): 230 x 460 V primary, 115 V secondary

VA Jefferson Micron
50 VA 636-1111-400 B050-0001-GA
75 VA 636-1121-400 B075-0002-GA
100 VA 636-1131-400 B100-0003-GA
150 VA 636-1141-400 B150-0004-GA
200 VA 636-1151-400 B200-0005-GA
250 VA 636-1161-400 B250-0006-GA
300 VA 636-1171-400 B300-0007-GA
350 VA 636-1181-400 B350-0008-GA
500 VA 636-1191-400 B500-0009-GA
750 VA 636-1201-400 B750-0010-GA
1 kVA 636-1211-400 E1K0-0008-GA
1.5 kVA 636-1221-400 E1K5-0009-GA
2 kVA 636-1231-400 E2K0-0010-GA
3 kVA 636-1241-400 E3K0-0011-GA
5 kVA 636-1261-400 E5K0-0012-GA

Micron GlobalTRAN Group A, built to IEC 60742 under the CB Scheme. The sheet prints 636-1131-400 and 636-1141-400 again at 2 and 3 kVA; by the series pattern those are 636-1231-400 and 636-1241-400. We confirm on the quote.

How to read a Jefferson 636 number

636 is the Jefferson control transformer line. The middle four digits set the voltage and VA together (1131 is 230 x 460 V to 115 V, 100 VA). The last three digits are the fusing: -200 primary fusing provision, -300 primary and secondary, -400 the CE series. 636-1161-300 is 250 VA, 230 x 460 V to 115 V, and crosses to Micron B250BTZ13JK.

Common questions

What Micron transformer replaces Jefferson 636-1131-200?

Micron B100BTZ13JK, 100 VA, Group A. Primary 220x440, 230x460 or 240x480 V. Secondary 110, 115 or 120 V.

What replaces Jefferson 636-1111-300?

Micron B050BTZ13JK, 50 VA, Group A. Ask for secondary fusing to match the -300.

What replaces Jefferson 636-1211-200 (1 kVA)?

Micron EF1K0BTZ13, a 1 kVA EconoTRAN unit, 180°C construction.

What replaces the Jefferson 400 series?

Micron GlobalTRAN Group A. 636-1131-400 crosses to B100-0003-GA.

Get it crossed and quoted

Send the Jefferson number and the quantity. We send back the Micron part and lead time.

Request a QuoteBook 30 Minutes to Review the Application

Related: GE 9T58 cross · HPS PT cross · Siemens MT cross · Square D 9070T cross · Micron control transformers by kVA · All cross references