Rittal Filter Fan to Pfannenberg Cross Reference

Replacing a Rittal SK filter fan? Here is the Pfannenberg PF fan for each Rittal series, SK 3237 through SK 3245, plus the SK 3139 and 3140 top mount fans. Match by cutout first, then airflow at the IP rating you need. Send the Rittal catalog number and we send back the Pfannenberg part number and a quote.

Request a QuoteBook 30 Minutes to Review the Application

Rittal to Pfannenberg filter fan cross

Rittal series Rittal CFM, IP54 Rittal CFM, IP55 Pfannenberg match Pfannenberg CFM, IP54 Pfannenberg CFM, IP55 Cutout, Rittal / Pfannenberg Pfannenberg voltages
SK 3237.xxx 11 n/a PF 11000 11 n/a 3.62 / 3.62 115, 230 V AC, 24 V DC
SK 3238.xxx 29 20 PF 22000 28 28 4.88 / 4.92 115, 230 V AC, 24, 48 V DC
SK 3239.xxx 59 42 PF 32000 38 38 6.97 / 6.97 115, 230 V AC, 24 V DC
SK 3239.xxx 59 42 PF 33000 SL 115 115 6.97 / 6.97 115, 230 V AC, 24 V DC
SK 3240.xxx 67 45 PF 42500 74 74 8.80 / 8.78 115, 230 V AC, 24 V DC
SK 3241.xxx 112 78 PF 43000 122 122 8.80 / 8.78 115, 230 V AC, 24 V DC
SK 3243.xxx 300 201 PF 66000 295 295 11.49 / 11.46 115, 230, 460 V AC
SK 3243.xxx 300 201 PF 65000 SL 249 249 11.49 / 11.46 115, 230 V AC
SK 3244.xxx 347 225 PF 67000 368 368 11.49 / 11.46 115, 230, 400/460 V AC
SK 3245.xxx 417 259 PF 67000 368 368 11.49 / 11.46 115, 230, 400/460 V AC
SK 3139.xxx (top mount) 203 n/a PFT 60700 218 n/a 10.15 / 11.50 115, 230, 400/460 V AC
SK 3140.xxx (top mount) 300 n/a PFT 61000 294 n/a 10.15 / 11.50 115, 230 V AC

CFM values are fan blowing into the enclosure and out through an exhaust filter, which keeps the cabinet under positive pressure. Pfannenberg free-air CFM is higher and is what our product titles show. Sizes in inches. Data from the Pfannenberg filter fan competitor comparison. Confirm the current datasheets before you release a drawing.

What to check before you swap

The Rittal SK 3237 to 3245 cutouts and the Pfannenberg PF cutouts line up within 0.04 in. On SK 3239 to 3245 the Pfannenberg cutout is the same or slightly smaller, so the PF fan goes into the existing hole. On SK 3238 the PF 22000 cutout is 0.04 in larger (4.92 vs 4.88 in), so open the hole slightly. The SK 3139 and 3140 top mount fans use a 10.15 in cutout. The PFT top mount fan needs 11.50 in, so plan a new cutout there.

Look at the IP55 column. Rittal airflow drops about a third at IP55 (SK 3244: 347 CFM at IP54, 225 CFM at IP55). The Pfannenberg fluted filter holds the same CFM at IP54 and IP55. If your spec calls for IP55, compare the IP55 numbers. SK 3245 at IP55 is 259 CFM, and the PF 67000 gives 368 CFM there. Rittal 24 V DC units come in RAL 7035 light gray only. Pfannenberg offers light gray and black.

Common questions

What Pfannenberg filter fan replaces a Rittal SK 3241?

PF 43000: 122 CFM at IP54 and IP55 through an exhaust filter, in an 8.78 in cutout that fits the 8.80 in Rittal hole.

What replaces a Rittal SK 3238 filter fan?

PF 22000: 28 CFM at IP54 and IP55, 4.92 in cutout. It also comes in NEMA 3R and 48 V DC.

Does the Pfannenberg fan fit the Rittal cutout?

Yes for SK 3237 and SK 3239 through SK 3245. The cutouts match within 0.03 in. SK 3238 needs the hole opened 0.04 in for the PF 22000. The SK 3139 and 3140 top mount fans use a smaller cutout than the PFT top mount fan.

Why compare IP55 airflow?

Rittal fans lose about a third of their airflow at IP55. Pfannenberg PF fans with the fluted filter keep the same CFM at IP55 as at IP54.

Get a quote or review the application

Send the Rittal catalog number, the voltage and the quantity. We send back the Pfannenberg match, the lead time and a quote. Not sure the fan is big enough? Book a time and we will run the heat load with you.

Request a QuoteBook 30 Minutes to Review the Application

More filter fan crosses: Hoffman, Rittal, Saginaw, Thermal Edge, Kooltronic, Seifert, Finder, Fandis.

More: all cross references · enclosure air conditioner cross reference · enclosure heat load calculator · Pfannenberg filterfans


Rittal is a trademark of Rittal GmbH & Co. KG. Pfannenberg is a trademark of Pfannenberg GmbH. Applied Control Inc. is not affiliated with Rittal.