Lapp ÖLFLEX VFD Cross Reference

Lapp ÖLFLEX VFD SLIM and ÖLFLEX VFD 2XL cross to the Tekima 365S series. Both are European engineered low-capacitance VFD motor supply cables with foil plus braid shielding and UL Type TC-ER approval.

Email a Part Number for a QuoteCall 248-425-9065

ÖLFLEX VFD to Tekima cross reference

Competitor series Description Tekima equivalent
ÖLFLEX VFD SLIM Compact 600V TC-ER, foil + tinned copper braid, 18 AWG to 2 AWG Tekima 365S 1xG (CV04G100 through CV04GB35)
ÖLFLEX VFD 2XL 2kV rated, larger AWG, symmetrical grounds Tekima 365S 3xG (CVFM0003 through CVFM0019)
ÖLFLEX VFD 2XL with Signal VFD cable with integral brake or sensor pair Tekima 365S 1xG + 1xP (CVFM0101 through CVFM0112)

Add the jacket color code to order: _GR for gray, _NE for black.

Notes on this cross

  • Tekima 365S symmetrical ground (3xG) construction starts at 10 AWG. Below that, the 1xG single ground construction is the correct cross.
  • Tekima 365S carries MTW 600V in addition to TC-ER, CIC/TC and WTTC, which widens where the same reel can be used.
  • Tekima runs a UL certified cut-to-length service. Specify the cut list and reels ship ready to install.

Check the UL listing before you substitute

Tekima builds two low-capacitance VFD families and they are not interchangeable.

  • 365S is UL Listed Type TC-ER (file E361258), XHHW-2, 600/1000V, direct burial, sunlight resistant, oil resistant I and II, FT4/IEEE 1202, WTTC, c(UL) CIC/TC-ER, and MTW 600V. This is the series that substitutes for competitor tray cable.
  • 361S is c(UR)us Recognized under AWM Style 2570 (file E314444) and carries an 80°C rating at 1000V on the UL side. It is not tray cable. Use it inside enclosures and machinery per NFPA 79 and UL 508A, not in an exposed tray run.

Every cross on this page is to 365S. If a quote comes back referencing 361S for a tray application, it is the wrong part.

Common questions

What is the Tekima equivalent of ÖLFLEX VFD SLIM?

Tekima 365S in the 1xG construction, part numbers CV04G100 through CV04GB35 depending on conductor size. Both are UL Type TC-ER, 600/1000V, with 100 percent foil coverage and an overall tinned copper braid.

What is the Tekima equivalent of ÖLFLEX VFD 2XL?

Tekima 365S in the 3xG symmetrical ground construction, part numbers CVFM0003 through CVFM0019. The symmetrical ground arrangement places three grounds around the phase conductors to control common mode current.

Does Tekima make a symmetrical ground VFD cable at 14 AWG?

No. Tekima 365S symmetrical ground construction starts at 10 AWG. At 14 and 12 AWG the 1xG single ground construction is what is available. If a specification mandates three symmetrical grounds at 14 AWG, Tekima cannot meet it.

Get a cross-referenced quote

Send the part number and the footage. We come back with the Tekima equivalent, the construction difference if there is one, and a price inside 48 hours.

Email a Part Number for a QuoteCall 248-425-9065

Tekima also runs a UL certified cut-to-length service. If you are buying full reels and scrapping the offcuts, tell us the cut list and we will quote it cut to size.

Email: christian.lauderback@appliedcontrolinc.com
Phone: 248-425-9065